- 6 -
Activation of the thermal protection is indicated by a steady pulsing of commu-
nication LED, switching off of the output circuit and the lack of its reactivation
possibility. After lowering the temperature to a safe value the output circuit will
remain switched off until restarted.
We do not recommend the use of remote bistable transmitters to control a
group of receivers due to the possibility of desynchronization of the activation
state (especially when operating on larger distances and/or simultaneous use
of local buttons on the receivers).
Devices of the F&Wave system
Transmitters
Receivers
Box Ø60
DIN rail
flush-mounted
Single relay
FW-R1P
FW-R1D
FW-RC5
Double relay
FW-R2P
FW-R2D
remote controls
Universal dimmer
FW-D1P
FW-D1D
FW-RC4
Roller blind controller
FW-STR1P
FW-STR1D
FW-RC10
Two-channel LED controller
FW-LED2P
FW-LED2D
Due to the nature of transmission and retransmission do not use the
same button in transmitter more often than every 2 seconds. Switching
of the receiver may be carried out with a short delay.