STR-3D controller is designed to control roller blinds (

�������

or other objects (e.g. gates) that are driven with single-phase 

alternating current electric motor with momentary switch (eg. 

bell).

The controller can operate as a stand-alone device (for opening/

closing of a single roller blind), but it is also possible to combine 

controllers into groups to central control multiple roller blinds. 

Roller blind motor starts after momentary passing of the N si-

gnal to one of the control inputs. The motor activates for the 

user-programmed time that allows to fully lift or lower the roller 

blind. The controller power supply is indicated by a green LED. 

Motor operation and direction of roller blinds movement is indi-

cated by the corresponding red ↓ or ↑ LED.

Purpose

Functioning

F&F Filipowski sp. j.

Konstantynowska 79/81, 95-200 Pabianice, POLAND

phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71

www.fif.com.pl; e-mail: biuro@fif.com.pl

Do not dispose of this device in the trash along with other waste!  

According 

to the Law on Waste, electro coming from households free of charge and 

can  give  any  amount  to  up  to  that  end  point  of  collec� on,  as  well  as  to  sto-

re the occasion of the purchase of new equipment (in accordance with the 

principle of old-for-new, regardless of brand). Electro thrown in the trash or 

abandoned in nature, pose a threat to the environment and human health.

Summary of Contents for STR-3D

Page 1: ...ift or lower the roller blind The controller power supply is indicated by a green LED Motor operation and direction of roller blinds movement is indi cated by the corresponding red or LED Purpose Functioning F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Do not dispose of this device in the trash al...

Page 2: ...mmed time Pressing the key when the roller blind is already in motion causes the roll er blind to stop Long press 0 5 s switches on the roller blind for as long as the key is pressed Each time you press the key the roller blind will move in the di rection opposite to the previous one Two local keys Each direction of movement has its own local key Short press 0 5 s switches on the roller blind to m...

Page 3: ...ve only in the de sired direction Roller blind will stop only after a preset time or by pressing any of the local control keys If during the execution of one center control command another one is issued with the instruction to move in the opposite di rection the roller blind will stop at first and after 1 5 s will then start to move in the opposite direction Time of roller blind acti vation can be...

Page 4: ...tional STR W wind sensor is used is detected 1 Disconnect the power supply 2 Mount the controller on the rail in the distribution box 3 Connect the controller accordingly to the selected scheme of operation The controllers can be powered from any phase of the mains also in the case of a multiple controllers oper ating under common central control It is important to retain a common N line and to co...

Page 5: ...ime in non volatile memory and then exit the programming mode which is indi cated by the constant U LED light Test run 1 Place the blind in the outmost top or bottom position 2 Press and hold for approx 4 s the key until the green U LED will begin to flash slowly The controller is now ready for programming 3 Short press the local control or key in the opposite direction to the current position of ...

Page 6: ... the learning mode The controller learning mode can be started only when the roller blind motor is turned off Operation with factory settings activation time set to 30 seconds is indicated in standby mode by short 0 1 s blinking of U LED repeated every 4 s The application examples listed below can be downloaded from the website www fif com pl from the product subpage 1 Wiring example one local but...

Page 7: ...65 V AC 4 central control direction 6 central control direction 7 local control direction 9 local control direction 10 motor power supply direction 11 power supply input 230 V AC L 12 motor power supply direction Wiring diagram ...

Page 8: ...oducts are covered by a 24 month warranty from the date of purchase The warranty is only valid with proof of purchase Contact your dealer or contact us directly F F Filipowski sp j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity along...