Time of activation can be programmed upon the assumed time 

of roller blind operation or by activating the roller blind for the 

test run:

Scheduling for the specified time

1. Press and hold (for approx. 4 s) the 

����

 key until the green 

U LED will begin to flash slowly. The controller is now ready 

for programming.

2. Short press 

����

 key – the controller starts to measure out 

the activation time, which is indicated by rapid flashing of U 

LEDs.

3. After the time has been measured out, press the 

����

 key 

again. The controller will save the elapsed time in non-volatile 

memory and then exit the programming mode, which is indi-

cated by the constant U LED light.

Test run

1. Place the blind in the outmost top or bottom position.

2.  Press and hold (for approx. 4 s) the 

����

 key until the green 

U LED will begin to flash slowly. The controller is now ready 

for programming.

3. Short press the local control 

��

 or 

����

 key (in the opposite 

direction to the current position of the roller blind). The con-

troller starts the motor and begins to measure out the time.

4.  After the time has been measured out, press any of the local 

control keys. The roller blind motor will stop and the controller 

will save the elapsed time in "non-volatile" memory and then 

exit the programming mode.

Scheduling time of activation

Summary of Contents for STR-3D

Page 1: ...ift or lower the roller blind The controller power supply is indicated by a green LED Motor operation and direction of roller blinds movement is indi cated by the corresponding red or LED Purpose Functioning F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Do not dispose of this device in the trash al...

Page 2: ...mmed time Pressing the key when the roller blind is already in motion causes the roll er blind to stop Long press 0 5 s switches on the roller blind for as long as the key is pressed Each time you press the key the roller blind will move in the di rection opposite to the previous one Two local keys Each direction of movement has its own local key Short press 0 5 s switches on the roller blind to m...

Page 3: ...ve only in the de sired direction Roller blind will stop only after a preset time or by pressing any of the local control keys If during the execution of one center control command another one is issued with the instruction to move in the opposite di rection the roller blind will stop at first and after 1 5 s will then start to move in the opposite direction Time of roller blind acti vation can be...

Page 4: ...tional STR W wind sensor is used is detected 1 Disconnect the power supply 2 Mount the controller on the rail in the distribution box 3 Connect the controller accordingly to the selected scheme of operation The controllers can be powered from any phase of the mains also in the case of a multiple controllers oper ating under common central control It is important to retain a common N line and to co...

Page 5: ...ime in non volatile memory and then exit the programming mode which is indi cated by the constant U LED light Test run 1 Place the blind in the outmost top or bottom position 2 Press and hold for approx 4 s the key until the green U LED will begin to flash slowly The controller is now ready for programming 3 Short press the local control or key in the opposite direction to the current position of ...

Page 6: ... the learning mode The controller learning mode can be started only when the roller blind motor is turned off Operation with factory settings activation time set to 30 seconds is indicated in standby mode by short 0 1 s blinking of U LED repeated every 4 s The application examples listed below can be downloaded from the website www fif com pl from the product subpage 1 Wiring example one local but...

Page 7: ...65 V AC 4 central control direction 6 central control direction 7 local control direction 9 local control direction 10 motor power supply direction 11 power supply input 230 V AC L 12 motor power supply direction Wiring diagram ...

Page 8: ...oducts are covered by a 24 month warranty from the date of purchase The warranty is only valid with proof of purchase Contact your dealer or contact us directly F F Filipowski sp j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity along...

Reviews: