background image

13

NOTE:

 The illustration shown is not to scale or its actual con

fi

 guration may vary

The Air Shadow Fan FP825**

Exploded-View

4

1

Figure 1

3

6

5

2

7

8

8 ref

9

10

8 ref

Summary of Contents for Air Shadow FP825 Series

Page 1: ...l No FP825 The Air Shadow Traditional Ceiling Fan Net Weight 12 47 kg 27 5 lbs WARNING Support Directly From Building Structure For Canada this fan must be secured directly to the building structure or ceiling joist Don t secure this fan to an outlet box ...

Page 2: ...wner s manual and safety information before installing your new fan Review the accompanying assembly diagrams 2 Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel 3 ...

Page 3: ... blade screwdriver One wire stripper Three wire connectors supplied Ceiling Canopy WARNING Do not install or use fan if any part is damaged or missing This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Fanimation Substitution of parts or accessories not designated for use with this product by Fanim...

Page 4: ...working loose Pull on the Downrod to make sure the clevis pin is properly installed Figure 2 Figure 2 Hairpin Clip Downrod Support WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician Motor Coupling Cover If your fan is to replace an existing light fixture turn electricit...

Page 5: ...urely tighten the two 3 16 24 x 3 8 setscrews in the downrod support Figure 2 NOTE The setscrews must be properly installed as described above or fan wobble could result 10 Slide the Motor Coupling Cover down until it touches the top of the Housing Figure 3 11 The fan comes with blue black gray and white leads Before installing fan measure up approximately 6 9 inches above top of Downrod Hanger Ba...

Page 6: ...es omitted for clarity 1 Using the 3 8 x 2 lag bolt and flat washer attach safety cable to ceiling joist or wood structural member The lag bolt will pass through the flat washer safety cable loop the junction box and into the building structure Figure 2 You will first drill a pilot hole into the building structure to prevent splitting or cracking 2 Securely attach the hanger bracket to ceiling jun...

Page 7: ...L to BLACK supply wire WHITE Receiver Unit wire AC IN N to WHITE supply wire WHITE Receiver Unit wire TO MOTOR N to WHITE fan wire BLACK Receiver Unit wire TO MOTOR L to BLACK fan wire BLUE Receiver Unit wire FOR LIGHT DOWN to BLUE light wire GRAY Receiver Unit wire REVERSE MODULE to GRAY wire Position all connected wires and receiver antenna to allow installation of ceiling canopy Using canopy sc...

Page 8: ...using water cleansers or harsh rags which can warp and ruin the blade and the finish CAUTION Do not use water when cleaning your ceiling fan It could damage the motor or the finish and create the possibility of electrical shock How to Operate Your C28 Remote Control 1 Operating Using Remote Transmitter Figure 1 Install 9 volt battery If not using for long periods of time remove battery to prevent ...

Page 9: ... tight 2 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 3 Some fan motors are sensitive to signals from solid state variable speed controls Solid state controls are not recommended choose an alternative control method 4 Tighten screws securely 5 Tighten set screw ...

Page 10: ...d before mounting the 5 light bowl 3 Mount 5 light bowl unit on accessory mounting plate with 3 screws and 3 lockwashers provided 4 Locate white and blue wires labeled FOR LIGHT Connect white to white and blue to black wires with wire nuts supplied CAUTION Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiri...

Page 11: ...the LK825 cont d Figure 5 Figure 6 Figure 7 Figure 8 5 Install lower housing 6 Install finial nut on end of nipple do not over tighten 7 Install glass shades not included 8 Install 60 watt med base bulbs not included ...

Page 12: ...O 10 Remote Control C28 Support Cable Bag Containing Ceiling Support Cable Cable Clamp Flat Washer Lag Bolt 3 8 x 2 TRADITIONAL LIGHT KIT ASSEMBLY LK825 6 5 Socket Light Kit Assembly AP82530 7 Lower Housing Light Kit P82515 1 Hanger Bracket Assembly APG610BL 2 Ball Downrod Assembly ADR1x6 3 Ceiling Canopy PG165 4 Motor Coupling Cover P81090 8 Hardware Bag s Containing HDWLK825 Wire Nut 7 Finial Nu...

Page 13: ...13 NOTE The illustration shown is not to scale or its actual configuration may vary The Air Shadow Fan FP825 Exploded View 4 1 Figure 1 3 6 5 2 7 8 8 ref 9 10 8 ref ...

Page 14: ...10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com Copyright 2007 Fanimation 2007 01 ...

Reviews: