background image

14

Trouble Shooting

WARNING

For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan.

Trouble

Probable Cause

Suggested Remedy

1.  FAN  WILL  NOT  START

1.  Fuse or circuit breaker blown.

2.  Loose power line connections to the fan, or loose 

switch wire connections in the switch housing.

3.  Reversing switch in neutral position.

1.  Check main and branch circuit fuses or circuit 

breakers.

2.  Check line wire connections to fan and switch wire 

connections in the switch housings.

CAUTION: Make sure main power is turned off !

3.  Make sure reversing switch position is all the way to 

one side.

2.  FAN  SOUNDS  NOISY

1.  Blades not attached to fan.

2.  Loose screws in motor housing.

3.  Screws securing fan blade holders to motor flywheel 

are loose.

4.  Wire connectors inside housing rattling.

5.  Motor noise caused by solid state variable speed 

control.

6.  Screws holding blades to blade holders are loose.

7.  Lower housing support set screw loose.

1.  Attach blades to fan before operating.

2.  Check to make sure all screws in motor housing are 

snug (not over-tight).

3.  Check to make sure the screws which attach the fan 

blade holders to the motor flywheel are tight.

4.  Check to make sure wire connectors in switch 

housing are not rattling against each other or against 
the interior wall of the switch housing.

CAUTION: Make sure main power is turned off !

5.  Some fan motors are sensitive to signals from solid-

state variable speed controls.  Solid-state controls 
are not recommended, choose an alternative control 
method.

6.  Tighten screws securely.

7.  Tighten set screw securely.

3.  FAN  WOBBLES

     EXCESSIVELY

1.  Setscrew in downrod support is loose.

2.  Setscrew in downrod/hanger ball assembly is loose.

3.  Screws securing fan blade holders to motor hub are 

loose.

4.  Blade holders not seated properly. 

5.  Hanger bracket and/or ceiling outlet box is not

securely fastened.

6.  Fan blades out of balance. 

1.  Tighten both setscrews securely in downrod support. 

2.  Tighten the setscrew in the downrod/hanger ball 

assembly. 

3.  Check to be sure screws which attach the fan blade 

holders to the flywheel are tight. 

4.  Check to be sure the fan blade holders seat firmly 

and uniformly to the surface of the motor housing. 
If holders are seated incorrectly, loosen the screws 
and retighten. 

5.  Tighten the hanger bracket screws to the outlet box, 

and secure outlet box. 

6.  Interchanging position of fan blades can redistribute 

the weight and result in a smoother operation. For 
example, exchange blades in positions 1 and 3 or 1 
and 4. If this does not improve wobble, exchange 2 
and 3 or 2 and 4.

4.  NOT  ENOUGH  AIR

     MOVEMENT

1.  If possible, consider using a longer downrod.  For 

example, use a 12” downrod instead of the 4.5” 
downrod that comes with your fan.

Summary of Contents for Cancun FP8009OB-220

Page 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model Nos FP8009OB 220 FP8011OB 220 The Cancun Ceiling Fans FP8009OB Net Weight 11 50 kgs Net Weight 13 50 kgs FP8011OB 220 220...

Page 2: ...IME WARRANTY Extends to the original purchaser of a Fanimation Fan Important Safety Instructions WARNING To avoid fire shock and serious personal injury follow these instructions 1 Read your owner s m...

Page 3: ...y Light Bulb FP8011OB 220 only One Phillips head screwdriver One stepladder One blade screwdriver One wire stripper Three wire connectors supplied Hardware bags 20 x 14 screws with lock washers blade...

Page 4: ...to be replaced Consult a qualified electrician if in doubt Energy Ef cient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceilin...

Page 5: ...ith holes in the downrod Se cure clevis pin with hairpin clip Tighten the two set screws with nuts in the downrod support Figure 3 BLUE BROWN AND ORANGE LEADS DOWNROD Figure 2 SET SCREWS AND LOCKING N...

Page 6: ...ING Failure to seat tab in groove could cause damage to electrical wires and possible shock or re hazard WARNING To avoid possible shock do not pinch wires between the hanger ball assembly and the han...

Page 7: ...with green colored insulation Securely connect wires with wire connectors supplied WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE...

Page 8: ...edge of the blade is fully seated against the blade arm With a Phillips screwdriver tighten 3 16 24x7 5 mm washer head screws with ber washers to secure the blade to the blade arm Figure 16 3 16 24 x...

Page 9: ...curely tighten all three screws Figure 19 Figure 19 SCREWS 3 ADAPTER ASSEMBLY 3a Securely attach the 9 pin switch cup connector to the wiring harness socket within the adapter assembly Figure 20a Figu...

Page 10: ...s Figure 22 Next install trim cover followed by the nial Do not over tighten Figure 23 3 Install pull chains and fobs Figure 24 Figure 24 Figure 23 To reduce the risk of electric shock disconnect the...

Page 11: ...ting Instructions 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box Figure 25 Figure 25 MAIN FUSE BOX 2 Check the operation of the fan by gently pulling o...

Page 12: ...220 AP800901OB 220 AP805204DBR AP800903OB HDWFP8009OB AP255BL 220 ADR1 45OB PG165OB AP260OB AP1115OB AMA8011OB 220 AP801102OB 220 AP805204DBR PPE14B60 220 AP800903OB P801102FW HDWFP8011OB Loose Hardwa...

Page 13: ...3 FP8009OB 220 FP8011OB 220 Exploded View NOTE The illustration shown is not to scale or its actual con guration may vary 1 2 3 4 5 6 7a 7c 7b 11 11 11 11 11 10 FP8009OB 220 ONLY FP8011OB 220 ONLY 9 8...

Page 14: ...other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state cont...

Page 15: ......

Page 16: ...Copyright 2010 Fanimation 2010 07 10983 Bennett Parkway Zionsville IN 46077 Toll Free 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Reviews: