1.   Read your owner's manual and safety information before installing your new fan.  Review the accompanying assembly

      diagrams.

2.   Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent

      power from being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a

      warning device, such as a tag, to the service panel.

3.   Be careful of the fan and blades when cleaning, painting, or working near the fan.  Always turn off the power to the ceiling

      fan before servicing.

4.   Do not insert anything into the fan blades while the fan is operating.

5.   Do not operate reversing switch until fan blades have come to a complete stop.

Important Safety Instructions 

Additional Safety Instructions

WARNING: To avoid fire, shock and serious personal injury, follow these instructions.

1.   To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.   All wiring must satisfy National (ANSI/ NFPA) Electrical Codes.  Use the National Electrical Code if Local Codes do not

      exist.  The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made

      or approved by a licensed electrician.

3.   The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 lbs. (fan and accessories not to

      exceed 35 lbs. or 17 kgs.).  Use only UL outlet boxes listed as acceptable for fan support.  Most outlet boxes commonly used

      for support of light fixtures are not acceptable for fan support and may need to be replaced.  Consult a qualified electrician if in

      doubt.

4.   

CAUTION:

  To reduce the risk of personal injury, mount the hanger bracket to an outlet box marked "Acceptable For Fan

      Support" using the hardware provided with your fan or the outlet box.

5.   The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.

6.   The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

7.   Follow the recommended instructions for the proper method of wiring your ceiling fan.  If you do not have adequate electrical

      knowledge or experience, have your fan installed by licensed electrician.

WARNING:

  To avoid fire, shock or injury, do not use a control not specifically approved for this fan.

WARNING:

  This product is designed to use only those parts supplied with this product and/or accessories designated specifically for 

use with this product.  Using parts and/or accessories not designated for use with this product could result in personal injury or 

property damage.

*

 

WARNING:

  To reduce the risk of personal injury, do not bend the blade flange (blade holder) when installing, balancing, or 

cleaning the fan.  Do not insert foreign objects in between rotating fan blades.

1.   

LIMITED LIFETIME MOTOR WARRANTY

 - If any part of your fan motor fails, due to a defect in materials or workmanship during the 

      lifetime of the original purchaser, Fanimation will provide the replacement part free of charge, when the defective fan is returned to our national

      service center.  Proof of purchase is required.  Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping 

      of the product for repairs or replacement.

2.   

ONE YEAR MOTOR LABOR WARRANTY

 - If your fan motor fails at any time within one year from the original purchase, due to defects

      in materials or workmanship, labor to repair the motor will be provided free of charge at our national service center.  Purchaser will be

      responsible for labor charges after this one-year period.  Customer shall be responsible for all costs incurred in the removal or reinstallation and

      shipping of the product for repairs or replacement.

3.   If any other part of your fan fails at any time within one year after original purchase, due to a defect in materials or workmanship, we will 

      repair, or replace, at our option, the defective part free of charge for parts and labor performed at our national service center.

4.   Because of varying climate conditions, this warranty does not cover changes in the finish, including rusting, pitting, corroding, tarnishing, or 

      peeling.

5.  This warranty is void and does not apply to damage from improper installation, neglect, accident, misuse, exposure to extremes of heat or 

      humidity, or as a result of any modification to the original product.

6.   All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that sold the fan or 

      Fanimation.

7.   Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty.

8.   Under no circumstances may a fan be returned without prior authorization from Fanimation.  The receipt of purchase must accompany 

      authorized returns and must be sent freight prepaid to Fanimation.  The fan to be returned must be properly packed to avoid damage in transit; 

      Fanimation will not be responsible for any damage resulting from improper packaging.

9.   It is understood that any repair or replacement is the exclusive remedy available from Fanimation.  There is no other expressed or implied 

      warranty.  Fanimation hereby disclaims any and all implied warranties, including, but not limited to those of merchantability and fitness for a 

      particular purpose to the extent permitted by law.  Some states do not allow limitations on implied warranties.  Fanimation will not be liable for

      incidental, consequential, or special damages arising out of or in conjunction with product use or performance, except as may otherwise be 

      accorded by law.  This warranty gives you special legal rights and you may also have other rights that vary from state to state.

10. A certain amount of wobble is normal and should not be considered a problem or a defect.

LIMITED LIFETIME WARRANTY

Extends to the original purchaser of a Fanimation Fan

*

 DAMP LOCATION CEILING FAN:  

For a Damp Location Ceiling Fan, you may only use light kits marked suitable for use in damp locations. 

Summary of Contents for Tropicana FP1600 Series

Page 1: ...he Tropicana Ceiling Fan Net Weight 19 lbs FP1600SO Std Oar Natural Wicker FP1610SO Std Oar White Wicker FP1600NO Nar Oval Natural Wicker FP1610NO Nar Oval White Wicker FP1620NO Nar Oval Natural Wicke...

Page 2: ...motor fails due to a defect in materials or workmanship during the lifetime of the original purchaser Fanimation will provide the replacement part free of charge when the defective fan is returned to...

Page 3: ...off each step As each step is completed place a check mark This will ensure that all steps have been completed and will be helpful in finding your place should you be interrupted Unpacking Instructio...

Page 4: ...ate and untwist the three motor leads Route the motor leads through the Downrod Hanger Ball Assembly 5 Loosen the two setscrews in the downrod support Align the clevis pin holes in the downrod with th...

Page 5: ...et must seat firmly against outlet box If the outlet box is recessed remove wallboard until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WAR...

Page 6: ...itch and reverse slide switch see page 7 2 Optional fan only wall slide control C1 see page 9 3 Optional fan light remote control C4 see page 8 4 Optional fan light slide wall control C2 or optional 2...

Page 7: ...on the other side of the outlet box 1 Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the supply grounding conductor this may be a bare wi...

Page 8: ...t Slide remote Receiver into the Hanger Bracket Figure 11 Connect wires as indicated Figure 12 Green Hanger Bracket and Hanger Ball wires to BARE ground wire BLACK Receiver Unit wire AC IN L to BLACK...

Page 9: ...o high speed before using the wall control To avoid accidental pull chain use shorten chain by cutting it 2 to 4 inches below switch body You can now use your speed control to select any of the 3 spee...

Page 10: ...Rubber Flywheel using the 10 32 x 1 2 Flywheel Screws Figure 17 2 Make sure the screws securing the Blades to the Flywheel are tight and that the Blades are properly seated on the Flywheel Attach the...

Page 11: ...If holders are seated incorrectly loosen the screws and retighten 5 Tighten the hanger bracket screws to the outlet box and secure outlet box 6 Interchanging position of fan blades can redistribute th...

Page 12: ...2 5 6 Hardware Bag Containing HDWFP1600 HDWFP1600 Ref No Parts List Model FP1600 1610 1620 Description FP1600 or FP1610 FP1620 Hanger Bracket Ceiling Canopy with Canopy Wicker Cover 1 3 Part P1608NA...

Page 13: ...17 6 7 4 5 19 3 2 1 1A The Tropicana FP1600 1610 1620 Exploded View Figure 18 NOTE The illustration shown is not to scale or its actual configuration may vary the wicker is removed for parts clarity G...

Page 14: ...945 Monument Dr Lebanon IN 46052 888 567 2055 FAX 765 482 5215 Visit Our Website www fanimation com 2002 08 Copyright 2002 Fanimation...

Page 15: ...ho Peso neto 8 5 kg 19 lb FP1600SO Remo est ndar mimbre natural FP1610SO Remo est ndar mimbre blanco FP1600NO Ovalada estrecha mimbre natural FP1610NO Ovalada estrecha mimbre blanco FP1620NO Ovalada e...

Page 16: ...para usar con este producto podr a resultar en lesiones personales o da os materiales ADVERTENCIA Para reducir el riesgo de lesiones personales no doble la pesta a del aspa retenedor al instalar equi...

Page 17: ...cada paso Ponga una marca a medida que vaya completando los pasos De esta forma se asegurar que se hayan completado todos los pasos y ser til para volver al lugar donde estaba en caso de interrupci n...

Page 18: ...are y desenrolle los tres cables del motor Tienda los cables del motor a trav s del conjunto de barra de bajada cubeta de suspensi n 5 Afloje los dos tornillos de fijaci n en el soporte de la barra de...

Page 19: ...onecte las aspas del ventilador hasta que el ventilador no est completamente instalado Al colgar el ventilador con las aspas conectadas se pueden da ar las mismas ADVERTENCIA C mo colgar el ventilador...

Page 20: ...na 7 2 Control deslizante optativo de pared para s lo 3 Control remoto optativo de ventilador y l mpara C4 vea la p gina 8 4 Control deslizante de pared de ventilador y l mpara optativo C2 o control d...

Page 21: ...los cables blanco y verde en un lado de la caja de distribuci n y los cables negro y azul en el otro lado de la misma 1 Conecte el cable de tierra verde de la cubeta de suspensi n y el cable de tierr...

Page 22: ...DOWN al cable de AZUL de la l mpara Coloque todos los cables conectados y la antena del receptor para permitir la instalaci n de la cubierta del techo Vuelva a instalar la cubierta del techo usando l...

Page 23: ...dente acorte la cadena cort ndola de 2 5 a 5 cm 2 a 4 pulgadas por debajo del cuerpo del interruptor Ahora puede usar el control de velocidad para seleccionar cualquiera de las 3 velocidades m s apaga...

Page 24: ...spas use los agujeros marcados con el n mero 4 NOTA DE INSTALACI N DE ASPA TORNILLOS 2 por aspa VOLANTE Figura 17 La limpieza peri dica de su nuevo ventilador del techo es el nico mantenimiento necesa...

Page 25: ...ficie del volante Si los retenedores est n mal asentados afloje los tornillos y vuelva a apretarlos 5 Apriete los tornillos del soporte colgante a la caja de distribuci n y sujete la caja de distribuc...

Page 26: ...piezas Modelo No FP1600 1610 1620 Descripci n FP1600 o FP1610 FP1620 Soporte colgante Cubierta del techo con tapa de mimbre de la cubierta 1 3 No de pieza P1608NA MC P1608WH WH P1608NA RS Estrecha ov...

Page 27: ...1 1A The Tropicana FP1600 1610 1620 Vista desarrollada Figura 18 11 NOTA La ilustraci n mostrada no est a la escala o su configuraci n real puede variar se ha quitado el mimbre para mayor claridad de...

Page 28: ...945 Monument Dr Lebanon IN 46052 888 567 2055 FAX 765 482 5215 Visite nuestro sitio web en www fanimation com 2002 10 S Copyright 2002 Fanimation...

Page 29: ...Ventilateur de plafond Poids net 19 lb FP1600SO Std Aviron Osier naturel FP1610SO Std Aviron Osier blanc FP1600NO troit Ovale Osier naturel FP1610NO troit Ovale Osier blanc FP1620NO troit Ovale Osier...

Page 30: ...entre les pales rotatives du ventilateur 1 GARANTIE VIE LIMIT E DU MOTEUR Si une partie du moteur du ventilateur ne fonctionne plus par suite d une d fectuosit de mat riau ou de main d uvre pendant l...

Page 31: ...eur par un lectricien agr MISE EN GARDE 1 V rifier si vous avez re u les pi ces suivantes Pour plus de commodit cocher chaque tape Chaque fois qu une tape est termin e la cocher Vous serez ainsi assur...

Page 32: ...Pour r duire le risque de blessure personnelle ne pas plier les supports des pales pour installer quilibrer ou nettoyer le ventilateur Ne pas ins rer d objets trangers entre les pales rotatives du ven...

Page 33: ...as connecter les pales du ventilateur tant que l installation du ventilateur n est pas finie Si on accroche le ventilateur avec les pales on risque d endommager les pales MISE EN GARDE Comment accroch...

Page 34: ...t C1 voir page 9 3 En option commande distance pour le ventilateur et l clairage C4 voir page 8 4 En option commande murale glissi re pour ventilateur et clairage C2 ou en option deux commandes murale...

Page 35: ...du bruit et pourrait s endommager Pour installer une commande d clairage en option distincte il est n cessaire d utiliser une autre borne dans la bo te prises Dans ce cas l le fil bleu du ventilateur...

Page 36: ...qu Figure 12 Les fils verts du support de suspension et de la sph re de support avec le fil D NUD mise la terre Le fil NOIR du r cepteur c a sous tension AC IN L au fil NOIR du circuit d alimentation...

Page 37: ...irette la vitesse rapide avant d utiliser la commande murale Pour viter une utilisation accidentelle de la tirette la raccourcir en la coupant entre 5 et 10 cm 2 4 po sous le corps de l interrupteur V...

Page 38: ...ond Pour nettoyer utiliser seulement une brosse douce ou un chiffon non pelucheux pour viter de rayer le fini Les agents de nettoyage abrasifs ne sont pas n cessaires et il faut les viter pour ne pas...

Page 39: ...mis correctement desserrer les vis et les resserrer 5 Serrer les vis du support de suspension la bo te prises et bien fixer la bo te prises 6 Le fait d intervertir la position des pales du ventilateur...

Page 40: ...1606NA RS Aviron standard Blanc 5 TRW4WH WH TRW4NA MC MCCRS TRW4NA RS TRW7NA MC TRW7WH WH N A N A N A Comment commander les pi ces Pour commander des pi ces de remplacement fournir les renseignements...

Page 41: ...19 3 2 1 1A The Tropicana FP1600 1610 1620 Vue clat e Figure 18 REMARQUE L illustration montr e n est pas l chelle et la configuration r elle peut varier l osier est enlev pour plus de clart 11 Fil d...

Page 42: ...945 Monument Dr Lebanon IN 46052 888 567 2055 FAX 765 482 5215 Visitez notre site Web www fanimation com 2002 10 F Copyright 2002 Fanimation...

Reviews: