background image

4

Please follow all applicable codes when installing this unit
1.  Equipment should be hung at its proper elevation by using    

temporary fixtures that can be removed after vibration  

 

hangers are installed. (Vibration isolation mounts provided  
by others)

2. Hanger may be fastened directly to the structure or  

 

  somewhere between suspended unit (be sure not to  

 

  over tighten the neoprene element).
3. Install  hangers.
4. Turn nuts on rod assembly clockwise one complete turn  

 

  on each hanger.  Repeat this procedure until temporary  

 

  hanging fixtures are loose and load of piping or equipment is  
  suspended completely on the vibration hangers.
5. Remove temporary hanger fixtures and level piping or  

 

  equipment by taking additional turns on the spring/top  

 

  hanger rod nut – clockwise to raise, counterclockwise to  

 

  lower as required.
6. If equipping fan with isolators (FC Clamps), they should  

 

  be attached at this time.
7. See wiring section to complete installation.

Mounting Illustration 1

Vibratio n

Mount

Detail

Please follow all applicable codes when installing this unit
1. Install wood supports to structure for fan mounting.
2. If equipping with vibration mounts, attach to supports.
3.  Attach fan to vibration mounts, supplied by others (be sure 

not to over tighten the neoprene element).

4. If equipping fan with isolators (FC Clamps), they should be    
  attached at this time.
5. See wiring section to complete installation.

Mounting Illustration 2

Please follow all applicable codes when installing this unit
1.  Create/Install angle wood supports to structure for fan mounting.
2. If equipping with vibration mounts, attach to supports.
3.  Attach fan to vibration mounts, supplied by others (be sure 

not to overtighten the neoprene element).

4.  If equipping fan with isolators (FC Clamps), they should be 

attached at this time.

5. See wiring section to complete installation.

Mounting Illustration 3

Mounting

Bracket

Vibration

Mounts

Fan

Bracket

Detail

Please note: Vibration Mounts and Hardware are not supplied with fan. fc clamps are sold separately.

Summary of Contents for FKD 8XL

Page 1: ...Installation and Maintenance Instructions for MODEL FKD INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN MOD LE FKD INSTRUCCIONES DE INSTALACION Y MANTENIMIENTO MODELO FKD...

Page 2: ...bonne combustion et pour l aspiration des gazs dans la chemin e afin d viter des refoulements Suivez le guide de chauffage du fabriquant ainsi que les r gles de s curit s comme celles qui sont dit es...

Page 3: ...sibles al conjunto de ventilador o impulsor 5 PRECAUCION Esta unidad contiene un impulsor expuesto No la utilice en sitios de f cil acceso por personas o animales USE PROTECCION PARA LAS MANOS Y CUIDE...

Page 4: ...section to complete installation Mounting Illustration 1 Vibratio n Mount Detail Please follow all applicable codes when installing this unit 1 Install wood supports to structure for fan mounting 2 If...

Page 5: ...uld be verified against code band If code band and color do not correspond to schematics above wire according to the code on the band 2 Color of capacitor leads may be reversed Fan operation will not...

Page 6: ...stallation 1 Vibratio n Mount Detail Veuillez suivre tous les codes applicables l installation de cet appareil 1 Installer les supports de bois la charpente pour l installation du ventilateur 2 S il e...

Page 7: ...riphas en 230 volts Remarques 1 Le branchement doit tre effectu par un professionnel La bobine de contr le doit tre branch e en s rie avec les contacts thermiques du moteur arriv es TK tel qu indiqu s...

Page 8: ...Mount Detail Favor acatar todos los c digos del caso al instalar esta unidad 1 Monte los soportes de madera en la estructura para montar el ventilador 2 Si la instalaci n lleva tirantes antivibratori...

Page 9: ...a 2 Puede que se hayan invertido los colores de los hilos Esto no afecta el funcionamiento del ventilador Ventilador Trif sico de 230 Voltios Notas 1 Se debe usar un contactor La bobina de control deb...

Page 10: ...un d faut d usine en mati re de qualit d ex cution ou de mat riau Il sera peut tre n cessaire de retourner le produit l usine Fantech accompag n d une copie du contrat de vente et du num ro d autoris...

Page 11: ...fecto en el material o en la mano de obra Es posible que el producto deba ser devuelto a la fabrica Fantech juntamente con una copia de la constancia de compraventa e identificado con el n mero de RMA...

Page 12: ...You may have additional rights which vary from state to state This warranty does not apply to any Fantech product or part which has failed as a result of faulty installation or abuse incorrect electri...

Reviews: