background image

FR Series Fan and balancing damper.

Balancing Damper

Wye with balancing damper.

When installing a DLX kit, a balancing damper has been included to allow for adjustment
of the system. The damper may be used where the grills will be connected using branches
of unequal length or where the flow will need to be balanced for any reason.

To Install The Damper:

1. The Damper must be installed on the branch with the least restriction. 

This is generally the duct that is shortest or has the fewest bends.

2. Drill a 

⁵₁₆

hole approximately 

1¹₂

from the edge on the flat side of the wye.

3. Place the washer over the threaded shaft on the damper.

4. Insert the damper, shaft first, into the hole just drilled.

5. Attach the handle using the wing nut.

6. Adjust the damper to balance airflow and tighten the wing nut to secure.

Flexible Duct Installation Hints 

Flexible insulated duct is strongly recommended where allowed by local code for bath-
room exhaust applications, where ducting passes through unconditioned space or where
noise is a factor. Failure to use insulation could result in excessive condensation buildup
within the duct, and undesirable sound levels within the room. For the quietest possible
installations, Fantech recommends a minimum of 8' of insulated flexduct between any
exhaust grill and fan. When using flexible type duct work, duct should be stretched as
tight and straight as possible. Failure to do so could result in dramatic loss of system per-
formance. Flexible duct should be connected to the fan with CB type clamps or duct tape.
All connections should be as airtight as possible to maximize system performance.

Installing DG Supply/Exhaust Grill

Side view grill and collar.

Mount Collar

Installing DG Supply/Exhaust Grill

If a Vent/Light combination kit is purchased, the VLC vent/lights are supplied with a sepa-
rate installation instruction replacing steps 1 through 4.

1. Select the grill mounting point within the area to be ventilated. To ease installation,

locations of framing beams within the walls or joists supporting the ceiling should be
considered. Collar/damper is provided with a perforated hanging strap for attachment
directly to a beam or joist. Allow sufficient space between the collar/damper and the
beam to attach the duct work. If the location of the grill does not allow direct attach-
ment, a cross-member mounted to the framing should be used.

2. Place the mounting collar/damper in the selected location and trace a circle onto the

surface. From the interior side of the room, cut through the surface. Please note: In
order to assure a smoother finish when mounting through a sheetrock or tile type ceil-
ing, it is recommended that a razor knife be used to make the cut.

3. From within the attic or crawl space, place the mounting collar into the hole until the

edge of the collar is flush with the interior wall or ceiling surface. Attach collar to the
support beam with the 2" wood screws provided. Attach duct work. Secure using CB
or FC clamps and/or duct tape. When installing the damper into rigid type ducting, FC
clamps or duct tape should be used.

PLEASE NOTE: 

When attaching flex duct to the collar/damper combination and an

immediate elbow is necessary, be certain that the elbow is installed with a "soft" bend
to allow damper blades to operate properly.

4. Snap the grill into the mounting collar/damper. Grill should be pushed tightly into

place for an airtight fit. If there is a gap between the collar and the ceiling it should be
caulked to avoid air leakage. For subsequent cleaning the grill can be pulled out and
cleaned.

Fantech “Your Ventilation Solutions Company”

3

Summary of Contents for FR Series

Page 1: ...INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR MODEL FR INSTRUCTIONS POUR L INSTALLATION ET L ENTRETIEN DU MOD LE FR INSTRUCCIONES DE INSTALACION Y MANTENIMIENTO DEL MODELO FR...

Page 2: ...n tubing allowing condensation to drain 3 Attach fan to the mounting bracket with the sheet metal screws provided Wiring box should be positioned for easy access Bracket is provided with rubber vibrat...

Page 3: ...ng DG Supply Exhaust Grill If a Vent Light combination kit is purchased the VLC vent lights are supplied with a sepa rate installation instruction replacing steps 1 through 4 1 Select the grill mounti...

Page 4: ...d with an internal lubricating material no additional lubrication is necessary Wiring Diagrams All Models Warning DO NOT CONNECT POWER SUPPLY until fan is completely installed Make sure electrical ser...

Page 5: ...tre plac e de fa on a avoir un acc s facile L attache est quip e d illets d isolement de vibration en caoutchouc pour emp cher la transmission du bruit par la structure Faites attention ne pas trop s...

Page 6: ...4 1 Choisissez le point du support de la grille dans la zone qui doit tre ventil e Pour faciliter l installa tion les emplacements des poutres d encadrement dans les murs ou les solives de plafond dev...

Page 7: ...l Assurez vous que l interrupteur du ventilateur est verrouill en position OFF fermer 1 Que toutes les unit s soient compatibles avec l utilisation de la commande vitesse variable 2 Que cette unit a d...

Page 8: ...nimo de ruido b El ventilador debe situarse donde haya acceso suficiente para el man tenimiento 2 Mediante los tornillos tirafondo fije el soporte de montaje NB o MB a una viga estructural en el siti...

Page 9: ...vitar fugas de aire Para la limpieza posterior la rejilla se puede extraer y limpiar Para la instalaci n del conjunto DLX se ha incluido una mariposa reguladora para ajustar el sistema Se puede utiliz...

Page 10: ...AL A MENOS DE SIETE 7 PIES DEL NIVEL DE OPERACION O DONCE SE ESTIME ACONSEJABLE PARA LA SEGURIDAD Conexi n El ctrica 1 Desenrosque los tornillos de montaje de la tapa de la caja de conexiones en el co...

Page 11: ...e la Factura de Venta para verificar la fecha de compra Garantie De Cinq 5 Ans Cette garantie remplace toutes les garanties pr c dentes Pour un renvoi l usine vous devez 1 Avoir obtenu un num ro d aut...

Page 12: ...First Thirty 30 Days FANTECH INC will repair or replace any part which has a factory defect in workmanship or material Product may need to be returned to the FANTECH factory together with a copy of t...