LOCATION

Dehumidifiers  are  designed  for  use  in  high  humidity  loca-
tions. Keep doors and windows closed for effective use and 
position the unit at least 10 inches (25 cm) from walls and 
other obstructions.

HUMIDISTAT

The  Humidistat  turns  the  unit 
on or off automatically. Operate 
initially on constant run until the 
desired  humidity  level  is 
achieved, then turn the control 
counterclockwise  until  the  unit 
cycles  off.  The  Humidistat  will 
now automatically maintain the 
selected level of humidity.

Constant Run

AUTOMATIC SHUT OFF

The dehumidifier has the automatic shut-off 
feature. The indicator light will signal when 
the water container needs to be emptied.

Constant Run

IMPORTANT: 

The water container must be fully inserted 

into the unit and the float must be hanging freely inside 
the water container for the automatic shut-off to func-
tion properly.

Empty  the  water  bucket  before  moving  the  dehumidifier.  It  is 
recommended to wait a minimum of 3 minutes before turning 
the unit on after the compressor stops running. This time allows 
internal systems to equalize and ensures a full torque start on 
the compressor.

AUTOMATIC EMPTYING

Water can be automatically emptied into a floor drain by attach-
ing a water hose to the threaded connector in the white plastic 
drip tray. The drip tray is mounted horizontally above the bucket. 
Once the bucket is removed, a hose can be easily attached.
The dehumidifier can also be placed over a floor drain. By remov-
ing the water container, the condensate will drop directly through 
the hole in the base into the drain.

DUST GUARD

A rear panel with a foam filter prevents dust from clogging the 
refrigeration coils. This filter should be cleaned monthly with a 
vacuum cleaner attachment or by washing with a mild detergent 
in  warm  water.  The  filter  panel  is  easily  removed  by  flexing  it 
outward in the centre, freeing the tabs in the sides of the cabinet.

DEFROST TIMER

Your dehumidifier is specially equipped with a defrost timer which 
enables the refrigerated coils to be defrosted once per hour. This 
timer turns off the compressor, thereby eliminating the refrigera-
tion  of  the  coils.  The  fan  continues  to  draw  air  over  the  coils 
causing the ice to melt and drop down into the reservoir.

CLEANING AND MAINTENANCE

When your dehumidifier requires cleaning, use a vacuum cleaner 
attachment or brush to clean the front grille. The air drying coil 
is best cleaned with a cloth and hot water. The dust guard filter 
can be washed or vacuumed. Always UNPLUG THE DEHUMIDIFIER 
before attempting to clean. The motor is permanently lubricated 
and does not require oiling.

TECHNICAL DATA

WARNING: 

This appliance must be grounded.

Recommended  limit  of  use:  Temperatures:  40°F  to  95°F 
(5°C to 35°C)
Relative Humidity: Greater than 30%

Summary of Contents for GD55S

Page 1: ...INSTRUCTIONS POUR Y RÉFÉRER À L AVENIR DEHUMIDIFIER DÉSHUMIDIFICATEUR Owner s Manual OPERATION AND MAINTENANCE MANUAL MANUEL D OPÉRATION ET D ENTRETIEN Operating Instructions 2 Guide d utilisation 3 THIS APPLIANCE MUST BE GROUNDED CET APPAREIL DOIT ÊTRE RELIÉ A UNE PRISE DE TERRE ...

Page 2: ... tray The drip tray is mounted horizontally above the bucket Once the bucket is removed a hose can be easily attached The dehumidifier can also be placed over a floor drain By remov ing the water container the condensate will drop directly through the hole in the base into the drain DUST GUARD A rear panel with a foam filter prevents dust from clogging the refrigeration coils This filter should be...

Page 3: ...ace Temperature in the operating space is too low Raise temperature with supplementary source Unit moves some water but not as much as expected Air temperature and Relative Humidity have dropped Check levels with calibrated humidity meter and or thermostat Unit is in defrost cycle Unit will start after cycle Air filter dirty or airflow obstructed Unit should have a minimum of 10 clearance all arou...

Page 4: ...DISTAT BLANC COMPRESSOR FAN MOTOR DE ICER CAPACITOR OVERLOAD FULL LIGHT LINE COM BLACK NEGRO WHITE BLUE BLANCO NO NC RED WHITE GREY HIGH BLACK NEGRO LOW RED BLANCO WHITE BLANCO WHITE BLUE BLACK BROWN GREEN BLUE B L A C K N E G R O L 1 3 S 2 1 C N HIGROMETRO ...

Page 5: ... do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives specific legal rights and the purchaser may have other rights which vary from state to state For more information regarding legal rights the purchaser may contact the local or state consumer affairs office or the appropriate state Attorney G...

Page 6: ...r éviter tout débordement Le déshumidificateur peut également être placé directement au dessus d une évacuation au sol En enlevant le réservoir l eau de condensation s écoulera directement à trav ers l orifice circulaire découpé dans le chassis de l appareil VITESSE DU VENTILATEUR Votre modèle sont muni d un commutateur à deux vitesses Pour une collection plus rapide de l humidité utiliser la posi...

Page 7: ...t ce que la température ambiante est trop basse Augmentez la température avec une source supplémentaire L appareil accumule de l eau mais moins que prévu La température de l air et l humidité relative ont baissés Vérifiez la température et l humidité relative avec un hygromètre calibré et ou un thermostat L appareil est en cycle de dégivrage L appareil recom mencera après le cycle Filtre à air est...

Page 8: ...STAT BLANC COMPRESSOR FAN MOTOR DE ICER CAPACITOR OVERLOAD FULL LIGHT LINE COM BLACK NEGRO WHITE BLUE BLANCO NO NC RED WHITE GREY HIGH BLACK NEGRO LOW RED BLANCO WHITE BLANCO WHITE BLUE BLACK BROWN GREEN BLUE B L A C K N E G R O L 1 3 S 2 1 C N HIGROMETRO ...

Page 9: ...autre Pour de plus amples informations concernant ses droits l acheteur peut communiquer avec le bureau de la protection du consommateur local ou de l État ou le secrétaire à la Justice de l État concerné GARANTIE LIMITÉE DU PRODUIT DISPOSITIONS GÉNÉRALES Aucune garantie ou assurance contenue ou exprimée dans les présen tes ne s appliquera lorsque les dommages ou le besoin de réparations sont la c...

Reviews: