1.-
Introduction.
Dear customer, in order to make reliable operating with our T-103 lifting tower we’ve
edited this operating manual. Please read it carefully before starts using the tower.
All our products have been submitted to more stringent proofs and controls during the
manufacturing process.
In order to maintain the guarantee of function and safety, original parts of the
manufacturer’s design must be used. The guarantee will be unabled if parts different
than the manufacturer ones are used to repair or modify the product in any other way.
We reserve the right to modify design and performance without prior notice when
contacting us with queries or ordering spare parts. In these cases we need the model
type, year of manufacture, and serial number.
2.- Technical Information.
Lifting tower T-103. This tower is designed to lift loads vertically up to different heights as
a support of lighting sets.
2.1.- Max. load: 150 kg.
2.2.- Min. load: 25 kg.
2.3.- Max. height: 5,3 m.
2.4.- Min. height: 1,70 m.
2.5.- Base area: 2 x 2 m.
2.6.- Folded base area: 0,37 x 0,37 m.
2.7.- Weight: 40 kg.
2.8.- Winch: 350 kg. maximum load winch with automatic brake to stop the load.
Certified in Düsseldorf according to DIN 15020 and VBG 8, with the number 93309.
2.9.- Cable: Steel DIN 3060. Quality 160 kg/mm
2
. Twisting – resistant. 4 mm. cable
diameter
2.10.- Construction material: Steel profiles DIN 2394.
2.11.- Four telescopic profiles system operated by steel cable and guided by
channelled steel pulleys with ball bearings.
2.12.- Profiles fixing to the desired height by safety steel ACC/12 catches.
2.13.- Adjustable stabilizing disc feet in the legs with rubber non slip supports.
2.14.- Anchor of the legs by safety catches.
2.15.- Bubble level to adjust the tower verticality.
2.16.- Antirust protection and electrolitic cadmiated.