The Touch supports 1 association group and can add Max 5 nodes in group 1. 

Association 
Group 

Nodes 

Send Mode 

Send Commands 

Group 1 

N/A 

N/A 

[1,5] 

Single Cast 

Send Notification Report CC/Hail CC when the 

Sensor is triggered. 

 

Association Group Info Command Class 

Association Group Info Report Command Class 
Profile:  General: NA (Profile MSB=0, Profile LSB=0) 
 

Association Group Name Report Command Class 

Group 1

Lifeline 

 

Notification Command Class 

Supported Notification type and Event: 
Notification Type: Access Control (0x06). 
Notification Events for Access Control: MANUAL UNLOCK OPERATION (0x02). 

 

Configuration Command Class

 

 

Parameter Number 
Hex / Decimal 

Description 

Default Value 

Size 

0x50 (80) 

To configure which command will be sent when the 

Sensor is triggered. 

Value=0, Send Notification Report. 

Value=1, Send Hail CC. 

Other values are ignored. 

0xFF (255) 

1, Value=0x55555555

Default=1

Size=4 

Reset to factory default setting and removed from 

the z-wave network 

N/A 

2, Value=0

Default=1

Size=1 

Reset to factory default setting 

N/A 

 