The Touch supports 1 association group and can add Max 5 nodes in group 1.
Association
Group
Nodes
Send Mode
Send Commands
Group 1
0
N/A
N/A
[1,5]
Single Cast
Send Notification Report CC/Hail CC when the
Sensor is triggered.
Association Group Info Command Class
Association Group Info Report Command Class
Profile: General: NA (Profile MSB=0, Profile LSB=0)
Association Group Name Report Command Class
Group 1
:
Lifeline
Notification Command Class
Supported Notification type and Event:
Notification Type: Access Control (0x06).
Notification Events for Access Control: MANUAL UNLOCK OPERATION (0x02).
Configuration Command Class
Parameter Number
Hex / Decimal
Description
Default Value
Size
0x50 (80)
To configure which command will be sent when the
Sensor is triggered.
Value=0, Send Notification Report.
Value=1, Send Hail CC.
Other values are ignored.
0
1
0xFF (255)
1, Value=0x55555555
、
Default=1
、
Size=4
Reset to factory default setting and removed from
the z-wave network
N/A
4
2, Value=0
、
Default=1
、
Size=1
Reset to factory default setting
N/A
1