background image

2

TOUCH-SCREEN PROGRAMMABLE THERMOSTAT

CH180-230V

Thank you for purchasing a 

FANTINI COSMI S.p.A.

 product.

Read this instructions manual carefully and always keep it handy for any consultation.

The documentation reflects the characteristics of the product. However, due to regulatory or commercial changes, 
customers are advised to check the availability of updates to this documentation on the website atFANTINI COSMI S.p.A.: 

pdf.fantinicosmi.it

OPERATION

The CH180-230V is a programmable thermostat for controlling heating and/or cooling systems. 
It has a customised temperature program on a time profile for every season, which can be changed as needed. 
The positive LCD display with white backlighting can also show an intuitive graph of the energy consumption of the entire 
system. 

CONTENTS OF PACKAGE

 

1 programmable thermostat

 

2 6/32UNC American standard thread screws to secure onto 503 flush mounting box (approximately Ø 3.5mm)

 

1 quick guide

Summary of Contents for CH180-230V

Page 1: ...E Fantini Cosmi S p a Via dell Osio 6 20049 Caleppio di Settala MI ITALY Tel 02 956821 I Fax 02 95307006 I info fantinicosmi it I http www fantinicosmi it Technical support supportotecnico fantinicosm...

Page 2: ...documentation on the website atFANTINI COSMI S p A pdf fantinicosmi it OPERATION The CH180 230V is a programmable thermostat for controlling heating and or cooling systems It has a customised tempera...

Page 3: ...ating mode 6 Bar graph for viewing messages and daily programming The function of the multi function keys varies depending on the situation and is described by the symbol which appears on the display...

Page 4: ...1 B U micro connection Software class A Minimum adjusting differential STD 0 3 5 K Reference thermal gradient 4 K h Maximum room temperature 45 C Storage temperature 10 C 60 C Electric insulation Dou...

Page 5: ...2 SELECTING THE OPERATING PROGRAM 15 4 3 JOLLY PROGRAM SETTING 16 4 4 SETTING AUTO and HOLIDAY PROGRAM TEMPERATURE 17 4 5 SETTING MANUAL and JOLLY PROGRAM TEMPERATURE 17 5 PARAMETER DISPLAY DISP 18 5...

Page 6: ...concerning the installation of electrical devices ATTENTION Make sure that the power supply is disconnected before performing installation The CH180 230V programmable thermostat must be installed on...

Page 7: ...ry the back panel off the body by applying pressure to the specific groove at the bottom Remove the insulating protection by unscrewing the specific waterproof screw Make the electrical connections re...

Page 8: ...ATTENTION Electrical connections must be made by qualified personnel ATTENTION Electrical connection operations must be done with the system s power disconnected Electrical connections must be made r...

Page 9: ...he display goes back to the main screen allows you to CONFIRM allows you to PROGRAM 3 1 DATE AND TIME SETTING Note pressing always allows you to go back to the previous page 2s PREMERE PREMERE ENTER 2...

Page 10: ...mode was previously selected 2s 2 1 12 01 01 01 18 23 0 SEL TEMP PROG DISP JOLLY OFF OFF 1 DAY PROGR UTENTE DATA E ORA INVERNO PROFILO VIS ORARIO BLOCCO NO DATA E ORA PROG PREMERE x1 INVERNO ENTER INV...

Page 11: ...TER OFF only for SUMMER In winter tE tC in summer tC tE Note Pressing ENTER allows you to go to the next day Pressing COPY allows you to copy the temperature profile being displayed to the following d...

Page 12: ...nformation on the set operating mode 2s 2 1 12 01 01 01 18 23 0 SEL TEMP PROG DISP JOLLY OFF OFF 1 DAY PROGR UTENTE DATA E ORA INVERNO PROFILO VIS ORARIO BLOCCO NO DATA E ORA PROG PREMERE x3 VIS ORARI...

Page 13: ...press the SEL key Pressing SEL allows you to enter the set password and unlock the keyboard 2s 2 1 12 01 01 01 18 23 0 SEL TEMP PROG DISP JOLLY OFF OFF 1 DAY PROGR UTENTE DATA E ORA INVERNO PROFILO V...

Page 14: ...profile You can set the following temperature levels tC tE tA OFF every half hour JOLLY TEMPORARY PROGRAM The device manages the system using a temperature that can be set over a variable amount of t...

Page 15: ...ay certain parameters set according to the active operating program 4 2 SELECTING THE OPERATING PROGRAM The programs are selected in cyclical order 2 1 2s TMAN 25 0 23 0 MAN SEL TEMP PROG DISP JOLLY O...

Page 16: ...ing status Set the time and day until you which you want to maintain the set temperature 4 3 JOLLY PROGRAM SETTING Select JOLLY mode by following the procedure described in the SELECTING THE OPERATING...

Page 17: ...perature value between 2 and 40 C 4 5 SETTING MANUAL and JOLLY PROGRAM TEMPERATURE You can set a TMAN and TJ temperature value between 2 and 40 C 24 4 TMAN 25 0 ENTER 24 4 3 DAY SEL TEMP PROG DISP JOL...

Page 18: ...arameters cyclically 5 1 DATE AND TIME 5 2 SEASON 12 01 01 01 18 24 2 SEL TEMP PROG DISP JOLLY OFF 3 DAY AUTO 12 01 01 01 18 24 2 SEL TEMP PROG DISP JOLLY OFF 3 DAY AUTO 1 2 12 01 01 01 18 ENTER 1 2 I...

Page 19: ...this section is only visible in AUTO and HOLIDAY mode in JOLLY the display shows the end date and time of the mode 12 01 01 01 18 24 2 SEL TEMP PROG DISP JOLLY OFF 3 DAY AUTO 1 2 PREMERE x2 12 01 01 0...

Page 20: ...re measured the previous day TMIN minimum room temperature measured from the previous day RESET Pressing DISP on the CURRENT MONTH PREVIOUS MONTH and CURRENT YEAR screens displays a graph with details...

Page 21: ...to modify the luminous intensity of the display at 10 levels 0 Off 12 01 01 01 18 23 0 SEL TEMP PROG DISP JOLLY OFF OFF 1 DAY 12 01 01 01 18 23 0 SEL TEMP PROG DISP JOLLY OFF OFF 1 DAY 2s 2 1 PROGR A...

Page 22: ...en 2 0 and 7 0 C or OFF 12 01 01 01 18 23 0 SEL TEMP PROG DISP JOLLY OFF OFF 1 DAY 12 01 01 01 18 23 0 SEL TEMP PROG DISP JOLLY OFF OFF 1 DAY 2s 2 1 PREMERE x2 ORA LEG SI PREMERE ENTER ORA LEG SI ORA...

Page 23: ...tatus to be managed Note the differential value that can be set is between 0 3 and 5 0 or STD default STD 12 01 01 01 18 23 0 SEL TEMP PROG DISP JOLLY OFF OFF 1 DAY 2s 2 1 LUCE ON 5S ENTER PREMERE x4...

Page 24: ...01 01 18 23 0 SEL TEMP PROG DISP JOLLY OFF OFF 1 DAY LUCE ON 5S ENTER 12 01 01 01 18 23 0 SEL TEMP PROG DISP JOLLY OFF OFF 1 DAY CELSIUS ESC 26 0 2s 2 1 PREMERE x6 PREMERE ENTER CELSIUS FAHRENHEIT 2s...

Page 25: ...DELTA 10 0 ENTER PREMERE ENTER LUCE ON 5S ENTER 12 01 01 01 18 23 0 SEL TEMP PROG DISP JOLLY OFF OFF 1 DAY PROGR AVANZ LUCE ON 5S INT LUCE 5 ORA LEG SI TA 5 0 CORREZIONE DIFF STD CELSIUS ITALIANO CHG...

Page 26: ...ate and time to the factory settings LUCE ON 5S ENTER 12 01 01 01 18 23 0 SEL TEMP PROG DISP JOLLY OFF OFF 1 DAY PROGR AVANZ LUCE ON 5S INT LUCE 5 ORA LEG SI TA 5 0 CORREZIONE DIFF STD CELSIUS ITALIAN...

Page 27: ...2005 Participating in the separate collection of products and batteries contributes to the correct disposal of these materials and therefore avoids possible negative consequences for the environment a...

Page 28: ...9 Caleppio di Settala MI ITALY Tel 02 956821 I Fax 02 95307006 I info fantinicosmi it I http www fantinicosmi it Technical support supportotecnico fantinicosmi it EXPORT DEPARTMENT Tel 39 02 95682222...

Reviews: