Fanvil Technology Co., Ltd
HQ Add: Level 3, Block A, Gaoxinqi Building, Anhua Industrial Park, Qianjin 1 Road, 35th District, Bao'An, Shenzhen, 518101 P.R. China
Shenzhen Tel: +86-755-2640-2199 Fax: +86-755-2640-2618 Suzhou Tel: +86-512-6592-0605 SEA Tel: +60-3-512-21997
Email: sales@fanvil.com support@fanvil.com Beijing Tel: +86-10-5753-6809
- 47
Field Name
Explanation
TR069 Settings
Enable TR069
Enable/Disable TR069 configuration
Enable TR069
Warning Tone
Enable or disable TR069 Warning Tone
ACS Server Type Select Common or CTC ACS Server Type.
ACS Server URL
ACS Server URL.
ACS User
User name for ACS.
ACS Password
ACS Password.
TR069 Auto
Login
Enable/Disable TR069 Auto Login.
b)
SYSLOG
Syslog is a protocol used to record log messages using a client/server mechanism. The Syslog server
receives the messages from clients, and classifies them based on priority and type. Then these messages
will be written into a log by rules which the administrator has configured.
There are 8 levels of debug information.
Level 0: emergency; System is unusable. This is the highest debug info level.
Level 1: alert; Action must be taken immediately.
Level 2: critical; System is probably working incorrectly.
Level 3: error; System may not work correctly.
Level 4: warning; System may work correctly but needs attention.
Level 5: notice; It is the normal but significant condition.