WATER ON TOP COOKING RANGE (NATURAL GAS)
FAR EAST EUROPE LTD
Installation instructions and user guide
Page 4 of 10
INSTALLATION
TECHNICAL DATA
Heat Inputs and Jet Sizes
All values are given using the net
Calorific Value.
NATURAL GAS G20 GOVERNED APPLIANCE
Heat Inputs Injector
kW
BTU/hr
Size (mm) Marking
2 Bar Burner (Far East) @ Full Rate
10.30
35,100
1.80
180
*2 Bar Burner (Far East)
@ Reduced Rate 7.30
##,###
1.80
180
2 Bar Burner (Teknigas) @ Full Rate
10.30
1.80
180
@ Reduced Rate 7.30
1.80 180
3 Bar Burner (Far East) @ Full Rate
19.20
65,500
2.10 2.1
*3 Bar Burner (Far East)
@ Reduced Rate 11.60
##,###
2.10 2.1
3 Bar Burner (Teknigas) @ Full Rate
15.55
1.80 180
@ Reduced Rate 9.70
1.80 180
Flamaire V6 Burner @ Full Rate
15.60
53,250
1.32 54
Flamaire V6 Burne r
@ Reduced Rate 9.00
##,###
1.32 54
JP1 Spider @ Full Rate
16.51
56,330
1.32
54
JP1 Spide r
@ Reduced Rate 9.80
##,###
1.32
54
JP12 Phoenix 12 jet @ Full Rate
19.60
66,900
1.2
1.2
*JP12 Phoenix 12 jet
@ Reduced Rate
7.20
##,###
1.2
1.2
JP21 Phoenix 21 jet @ Full Rate
21.90
74,700
1.0
1.0
*JP21 Phoenix 21 jet
@ Reduced Rate
7.90
##,###
1.0
1.0
NATURAL GAS G25 GOVERNED APPLIANCE
Heat Inputs Injector
kW
BTU/hr
Size (mm) Marking
2 Bar Burner (Teknigas) @ Full Rate
10.40
35,500
1.98
200
2 Bar Burner
(Teknigas) @ Reduced Rate 7.30
1.98
200
3 Bar Burner (Teknigas) @ Full Rate
15.55
53,000
1.98 200
3 Bar Burner
(Teknigas) @ Reduced Rate 9.70
1.98 200
Flamaire V6 Burner @ Full Rate
15.60
53,250
1.57 52
Flamaire V6 Burner
@ Reduced Rate
9.00
1.57 52
NATURAL GAS G20 UNGOVERNED APPLIANCE
Heat Inputs Injector
kW
BTU/hr
Size (mm) Marking
2 Bar Burner (Teknigas) @ Full Rate
9.88
33,500
1.80
180
2 Bar Burner (Teknigas)
@ Reduced Rate 7.30
1.80
180
3 Bar Burner (Teknigas) @ Full Rate
16.00
54,500
1.80 180
3 Bar Burner (Teknigas)
@ Reduced Rate 9.70
1.80 180
Flamaire V6 Burner @ Full Rate
15.60
53,250
1.32 54
Flamaire V6 Burner
@ Reduced Rate
9.00
1.32 54
Summary of Contents for CEFT54
Page 19: ...INTENTIONALLY BLANK...