TOPPING UP THE OIL-DYNAMIC CIRCUIT
(fig.
f8
)
You need to top up the oil-dynamic circuit after a long period
of work, when you note a power loss.
Put the riveting tool
(DWELL AND NOT FED)
in a horizontal
position
and remove the plug
(F)
, by means of a 5 mm Allen wrench
(equipped with the riveting tool); during this operation, check
the oil level in order to avoid any overflowing. Then, slowly
pour the oil
PANOLIN HLP ISO 32
into the bellows container
(O)
which shall be screwed to its seat on the plug
(F)
.
While
keeping the riveting tool in a horizontal position and starting
air feeding, push the tensile strength button and make the
riveting tool carry out some cycles until air bubbles inside the
container (
O
) stop coming out. This condition indicates that
the topping up of the oil has fully been achieved. At this point
stop the air feeding
and, while keeping the riveting tool in
a horizontal position, unscrew and close up the container
(O)
and the plug
(F)
.
WARNING:
it is very important to follow the about mentioned
instructions and use gloves. If you need to empty fully the
hydraulic circuit, you must put the oil in a suitable container
and contact a Company that is authorized to discharge any
waste.
Before disconnecting the compressed air hose,
make sure that it is not under pressure!
ATTENTION:
Make sure that the oil filter cap (
F
)
is tightened at a torque corresponding to
Min. 5
Nm ÷ Max. 8 Nm.
We recommend to use oil
PANOLIN HLP ISO 32
DIN 51524-2/HLP
or similar.