TOPPING UP THE OIL-DYNAMIC CIRCUIT
(fig.
f8
)
you need to top up the oil-dynamic circuit after a long period
of work, when you note a power loss. Put the riveting tool
(
DWELL AND NOT FED
) in a horizontal position and remove
the plug (
F
), by means of a 5 mm Allen wrench (equipped
with the riveting tool); during this operation, check the oil
level in order to avoid any overflowing. Then, slowly pour the
oil
PANOLIN HLP ISO 32
into the bellows container (
O
) which
shall be screwed to its seat on the plug (
F
). While keeping the
riveting tool in a horizontal position and starting air feeding,
push the tensile strength button and make the riveting tool
carry out some cycles until air bubbles inside the container (
O
)
stop coming out. This condition indicates that the topping up of
the oil has fully been achieved. At this point, while keeping the
riveting tool in a horizontal position, unscrew the oil container
(
O
) and close it again.
do not push the tensile strength button during this operation.
Go on by closing the oil tank plug (
F
).
WARNING:
it is very important to follow the about mentioned
instructions and use gloves. If you need to empty fully the
hydraulic circuit, you must put the oil in a suitable container and
contact a Company that is authorized to discharge any waste.
O
F
min. 5 Nm
max. 8 Nm
N
M
18 mm
14 mm
A
f5
f6
f7
f8
ATTENTION!
Before disconnecting the compressed air hose,
make sure that it is not under pressure!
ATTENTION:
Make sure that the oil filler cap (
F
)
is tightened at a torque corresponding to
Min. 5
Nm ÷ Max. 8 Nm.
We recommend to use oil
PANOLIN HLP ISO 32
DIN 51524-2/HLP
or similars.