19
GB
RAC 181
RAC 181
Revisione - 01
Date 04-2017
G
N
N
N
M
M
C
f6
f7
f10
f9
f8
Suction always ON (
pic.
f6-f7-f8-f9-f10)
From the "
ON
" position, with the supplied pin (
N
), push the selector (
D
) towards the inside of the riveting tool, as in the picture (pic.
f6
). Press and hold the lever (
G
) and, at the same time , push in the locking device (
M
) (pic.
f7-f8
). To return to the controlled suction
press the locking device (
M
) on the opposite side (pic.
f9
).
When the nail container (
C
) is full, do not operate the riveter, unscrew the container (
C
) and empty it (pic.
f10
).
PLEASE DISPOSE OF NAILS CAREFULLY!
WARNING:
When the riveting tool is used in the absence of nails tank (
C
), it is essential to fit the baffle (
T
) and the relative reduction
(
S
) (pic.
F12
), in order to avoid injury to the operator and / or persons close to him.
D