Perform manual programming relay.
Manual programming must be performed
by changing the following parameters in se-
quence:
1. Address
with which the relay is identified
within a DUO installation (factory setting
211, permitted values 211-220).
2.
Activation time
(in seconds) for which the
relay is activated (factory setting 001 s,
permitted times 000-099). The
value 000
corresponds to bistable operation
.
3. Operating mode
(factory setting 000, per-
missible values 000, 002, 006). Determines
how the C/NO contact is activated (Table
1).
4. Additional address
with which the actua-
tor can be identified
. (Factory setting emp-
ty, permitted addresses 001-200 and 211-
220).
It is not possible to skip steps in the sequence.
It is not possible to change the activation time
without first setting the relay address (even
if the address, already stored in the memory,
is already the desired one). On the other
hand, it is possible to leave the programming
mode before completing the sequence if you
are not interested in the subsequent steps.
For example, it is possible to change only the
relay address, leaving the rest unchanged. At
this point, once the value has been entered
(e.g. 211), you can exit programming. The va-
lues of the parameters to be set in the relay
must be previously stored (for example) in
the buttons of a video door phone/intercom
(it is possible to store in button 1 the address
211, in button 2 the time 005 seconds, in but-
ton 3 the operating mode 006 and in button 4
the additional address 100).
Once into the programming:
The device is ready to receive the
relay ad-
dress
; then press button 1 on the intercom
in which the value 211 of the above exam-
ple is stored. A confirmation tone will be
heard;
the device is ready for programming the
activation time
; if no further programming
is required, exit, otherwise press button 2.
A confirmation tone will be heard;
the device is ready for the programming
of the
operating mode
; if no further pro-
gramming is required exit, otherwise press
button 3. A confirmation tone will be heard;
the device is ready for the programming
of the
additional address;
if no further
programming is required, exit, otherwise
press button 4. A confirmation tone will be
heard.
Exit programming. If you made a mistake,
repeat the procedure from the beginning. As
an alternative to the video door phone/inter-
com, the digital keypad of an external door
station can be used to enter the values of the
relay parameters.
Enter manual IN/GN port programming.
To enter the
“input port”
programming mode,
the
JP
terminal must be jumpered with
IN
;
JP
IN
GN
(the red LED flashes quickly).
To carry out programming,
directly
connect the door unit or apartment
station with which the actuator is to
be programmed to its terminals and
disconnect the rest of the riser.
Exit manual IN/GN port programming.
To exit the
“input port”
programming:
you must remove the jumper between the
JP
and
IN
terminals;
;
JP
IN
GN
(the red LED will return to flash slowly).
Perform manual programming of the
IN/GN port.
The sequence of parameters to be changed is
as follows:
1. Address
which identifies the input port wi
-
thin a DUO installation; (factory 221, per-
mitted values 221-230. Or 211-220 only
if IN/GN is used to activate C/NA/NC of
another 2281Q).
2. Command sent by the device
when clo-
sing/opening the IN-GN contacts as shown
in Table 2; (factory setting 000, permitted
values 000-001-004-128-129-132).
3. Destination address of the command;
when the IN/GN contacts are closed (fac-
tory setting no value, permitted values
001-253)
.
As the relay, it is not possible to skip steps
in the sequence. It is not possible to change
the command to execute without first setting
the door address (even if the address already
stored is the desired one). On the contrary,
it is possible to exit the programming in ad-
vance, if you want to modify only the first pa
-
rameters of the sequence. The values of the
parameters to be set in the input port must
be previously stored (for example) in the
buttons of a video door phone/intercom (it is
possible to store in button 1 the address 221,
in button 2 the command 001 and in button 3
the destination address 231).
Once we get into the programming:
The device prepares to receive the
port
address
; then press button 1 of the door
phone in which the value 221 of the above
example is stored. A confirmation tone will
be heard; if
the relay address of another
2281Q has been stored (actuator acti-
vation from another actuator), exit pro-
gramming;
the device is ready for programming the
type of command sent
; if no further pro-
gramming is required, exit, otherwise press
button 2. A confirmation tone will be heard;
the device is ready for the programming of
the
destination address of the command
;
if no further programming is required exit,
otherwise press button 3. A confirmation
tone will be heard;
Exit programming. If you made a mistake,
repeat the procedure from the beginning. As
an alternative to the video door phone/inter-
com, the digital keypad of an external station
can be used to enter door parameter values.
Manual return to factory programming
(default).
To restore factory programming and there-
fore cancel all the changes made during the
programming phase, you can proceed via
Bluetooth or manually. In the latter case it is
necessary to:
enter relay or input port programming as
described in the
“enter manual program-
ming”
paragraphs;
To reset all relay parameters to the fac-
tory defaults
, program the value
211
into
the relay address;
To reset all input port parameters to the
factory default value
, program the value
221
into the input port address;
Exit programming.
Code
Activation of services from internal stations only
000
Activation of services also from external stations
002
call
forwarding
006
Table 1.
Relay operating mode
Table 2. Codes for command selection sent by IN-GN on
contact closing contact opening
(*)The command is sent to all devices for
which the destination address does not
need to be programmed.
Note
: To display the door open message on
EX3262C/EX362, it is necessary to enable
mode 7 of system programming.
Door
open/closed
warning*
000
128
Door lock activation (set destination address)
001
129
Floor call to internal station (set destination address)
004
132