Adjusting the Magnetic TOF
Use this setting to position the magnetic data at the correct distance from the leading edge of
the card.
•
The Magnetic TOF is the distance from the edge of the card to the Start Sentinel (SS).
•
The Start Sentinel marks the beginning of the encoded data. (
Note:
According to the
magnetic recording standard (ISO 7811), the correct Start Sentinel distance is 0.293
inches ± 0.020 inches (7.44 mm ± 0.51 mm) from the leading edge of the card.)
Step Procedure
1
From the application program, print and encode a test card.
•
Measure this distance by making the data visible using a magnetic
viewer or developer solution.
•
Alternatively, use a Magnetic Card Analyzer to measure the Start
Sentinel distance.
2
•
If the Start Sentinel is too far from the leading edge of the card,
reduce (or make negative) the Magnetic TOF.
OR
•
If the Start Sentinel is too close to the leading edge of the card,
increase (or make positive) the Magnetic TOF.
3 Select
MENU
,
Setup Printer
,
Encoder Settings
and
Magnetic TOF
.
4 Record
the
Magnetic TOF
value on the test card last printed.