FITTING AND OPERATING 

INSTRUCTIONS FOR FARHO HEATERS

WARNING

Please read these instructions carefully and keep them for future queries.

It is recommended that heaters are being installed and accredited by a qualified 
electrician following Low Voltage Regulations. Any claim presented will be deemed 

as invalid if the prevailing regulations have not been met.

GENERAL INFORMATION

Thank you for purchasing a Farho heater.

Farho, is a unique heating system designed, developed and produced by Farho based on a 
heating conducting fluid with a very high heat inertia. Farho heaters put together a great 
number of the advantages of existing heating systems such as the use of injected aluminum 
and electricity as a source of energy easy to use and control and Farhoil, a patented fluid 
elaborated just for Farho. Farho heaters are available in different types giving therefore 
solutions for everyone.

Farho heaters have been designed and are manufactured in accordance with appliance 
requirements pursuant to EN 60950, EN 300 220, EN 301 489, EN 60335-1 y EN 60335-
2-3 standards.

Correctly sized, the heater will provide sufficient heat to keep the space in which it has 
been fitted warm in a very efficient way.

IMPORTANT: 

Always disconnect the electricity supply from the power point before any 

maintenance operations.

DO NOT COVER heater´s surface. Inflammable items must not be placed on the heaters. 
Heaters should not be used to dry out clothes, towels… These items as well as other such 
as spray cans and volatile substances or objects must be kept away at least 2cm from 
the radiator.

Summary of Contents for ECG-11

Page 1: ... and electricity as a source of energy easy to use and control and Farhoil a patented fluid elaborated just for Farho Farho heaters are available in different types giving therefore solutions for everyone Farho heaters have been designed and are manufactured in accordance with appliance requirements pursuant to EN 60950 EN 300 220 EN 301 489 EN 60335 1 y EN 60335 2 3 standards Correctly sized the ...

Page 2: ...indoors Indicatively each degree Celsius above 21ºC can represent an increase in energy consumption up to 7 The fact of raising the setpoint temperature does not mean that the comfort temperature is reached more quickly so it is advisable to choose a temperature close to 21ºC and wait for the radiator to warm the room up Use it when it is really necessary With the heater programming help it can be...

Page 3: ...sy use Farho EG models can be programmed in up to six independent operating periods for each day of the week and it can also be controlled from the front panel This heater incorporates a open window detection function which can be enabled from the menu When operating on this mode the heater will pause the operation i e stop consuming whenever it detects a drop of 2ºC or more on less than 5 minutes...

Page 4: ...OW TO LOCK AND UNLOCK THE SCREEN 1 Press the keys and simultaneously for the screen approximately 3 seconds CHANGE TEMPERATURE To raise or lower the room temperature simply press buttons or until the temperature indicator displays the desired temperature level The Farho heater will automatically adjust the heat emission efficiently until reaching the temperature level set HOW TO KNOW IF THE HEATER...

Page 5: ...t day of the week to display its program CUSTOMISE PROGRAMS This model enables you to customise in a centralised fashion operating programmes of radiators so that these meet your heating needs You can customise programs for every day of the week up to six operating time slots 1 Press the key 2 The indicator will position itself in front of Programs Press the key 3 Press the key twice The indicator...

Page 6: ... 2 The indicator will position itself in front of Programs Press key to position the indicator in front of Configuration 3 Press the key 4 The indicator will position itself in front of Time Press the key twice to position it in front of Offset HOW TO ENABLE OR DISABLE OPEN WINDOW DETECTION FUNCTION TO ENABLE OPEN WINDOW DETECTION 1 Press the key The indicator will position itself in front of Prog...

Page 7: ...ings Any programs that have been configured by the user will be replaced by a standard program 1 Press the key 2 Press the key once Which will make the replaced indicator position itself in front of Config 3 Press the key 4 Press the key four times which will make the indicator position itself in front of Reset 5 Press the key 6 The text Sure No will be displayed Press or to change the text to Sur...

Page 8: ... the week and it can also be controlled from anywhere with its automation model The XP LST has the same characteristics as the XP and therefore it is operated as the XP except the following the max surface temperature is limited to 40º Celsius in order to fulfil a European Regulation that requires limited temperature on heaters that are to be installed in schools nurseries and hospitals in order t...

Page 9: ...OK and for every hour that they want the booster mode on If you want to activate the booster just for one hour press the button once if the user wants it to be running for two hours press it twice and for three hours press it three times If the user wishes to deactivate the booster feature the OK and button should be pressed until the display shows the message BOOSTER OFF HOW TO BLOCK AND UNBLOCK ...

Page 10: ...ront of Activate Press the key The programmes have now been activated Note If on reaching this step the indicator is positioned in front of the word Deactivate instead of Activate this means that programmes had already been activated TO DEACTIVATE PROGRAMMES To deactivate programmes follow the steps given below 1 Press the key 2 The indicator will position itself in front of Programmes Press the K...

Page 11: ...r the hour required for the time zone to start 11 Press the key 12 Press the and key to enter the minute required for the time zone to start 13 Press the key A menu will come up showing the time zone that is being implemented and the word OFF which indicates that time at which the time zone in question finishes should be entered 14 Press the and keys to enter the hour at which the time zone is to ...

Page 12: ...lickering but the room temperature is is above the pre set operating temperature disconnect the heater wait for a few seconds and turn it on again Perhaps you have set the heater operating output and this is not receiving permission from any central unit to come into operation If this is the case you must enter MENU SETTINGS POWER and press the button until it reaches 0 If none of the above work c...

Page 13: ...10x58x980 14 4 8 1 330 770x58x980 15 5 10 1 650 930x58x980 22 7 12 2 000 1090x58x980 26 8 MODELS POWER DIMENSIONS WEIGHT ECG WEIGHT XP XP XP LST ECG W width x depth x height kg kg 3 330 370x 590 58 x 95 98 7 42 7 6 5 550 530x 590 58 x 95 98 11 06 11 5 7 770 690x 590 58 x 95 98 15 15 58 9 990 850x 590 58 x 95 98 18 76 19 6 11 1220 1010x 590 58 x 95 98 22 62 23 48 13 1430 1170x 590 58 x 95 98 26 3 2...

Page 14: ...lated wall If necessary the surface s insulation should be increased Heaters should not be fitted within the safety protection area limit in bathrooms that is stipulated in each country s regulations and the minimum distances shown on the figure below should be respected Beside a wall 100 yield With a shelf or sill above 90 yield In a recess 85 yield FITTING The Farho heater will be mechanically s...

Page 15: ... including carrier and labor costs After the second year any electronic flaw can be repaired in Farho s Technical Service Department but carrier and labor costs will be charged to the client Flaws in the aluminum body such as leaks or paint flaws are covered by the guarantee meaning that the guarantee holder will not have to cover any labor costs or materials that need to be replaced The guarantee...

Page 16: ...DRESS STARTUP DATE INSTALLER INSTALLER INSTALLER S NUMBER AND SEAL DATE OF PURCHASE DISTRIBUTOR THERMAL RADIATOR FARHO VERY IMPORTANT If you wish to report any incident please consult factory by calling Have a look at the manuals in our web ...