Assembly - 1370, 1385, 1395, 13114 Backsaver Auger
68
Figure 200
Apply teflon tape to the threads (Item 1) of the
hydraulic hose fitting, then install and tighten the
male quick coupler fitting (Item 2)
[Figure 200]
.
Repeat for second quick coupler hose.
Figure 201
Locate one adapter fitting (Item 1) and 90° elbow
fitting (Item 2)
[Figure 201]
.
Install one hydraulic quick coupler hose assembly
(Item 3) into the 90° elbow
[Figure 201]
.
Figure 202
Locate one 90° elbow (Item 1) and place in a vise
[Figure 202]
.
Apply teflon tape to the threads (Item 1) of the
hydraulic hose fitting, then install and tighten
quick coupler hose assembly into the 90° elbow
(Item 2)
[Figure 202]
.
Apply teflon tape to the threads of the 90° elbow.
Locate, install and tighten the 1/2” ball valve (Item
3) onto the 90° elbow
[Figure 202]
.
Locate one adapter fitting (Item 4)
[Figure 202]
.
Apply teflon tape to the threads of the adapter
fitting, then install and tighten adapter fitting into
the 1/2” ball valve (Item 3)
[Figure 202]
.
1
1
2
3
2
4
3
1
2
4
1
1
2
Summary of Contents for 1370