d) If you want to spray higher, you could connect two spraying poles, which will
increase the total length.
e) This machine has three different kinds of nozzles. You could use the nozzle
according to different conditions.
Model of the
Nozzle
Diameter of
the Nozzle
(
mm
)
Flow
(
L/min
)
Working
Pressure
(MPa)
The
amount of
Nozzle
Taper Nozzle
1.0
0.8
0.15
~
0.35
1
Sector Nozzle
0.7
0.48
0.15
~
0.4
1
F Nozzle
1.5
1.2
0.15
~
0.25
2
Note
: The data in the table is the trial value of our company and not the confirmed value.
The amount of spraying mist and working pressure may change with the environment.
4. Add Liquids
a) Please keep this machine on the actinic ground when adding liquids.
b) Please use the filter screen when you are adding liquids. The filter screen can
protect the liquid plug from jam, for the jam can result in abnormal jet.
c) Please be slow when adding chemical in order to avoid over brimming. Once
over brimmed, please wipe it dry and clean with gauze so that the chemical
doesn’t flow into the battery and electric pump. The chemical liquids, can
corrupt the electric equipment and shorten the life of this machine.
d) It is strictly prohibited to use menstruums easy to curdle when meeting heat for
the heat generated by the working of liquid pump is easy to curdle that
menstruum so that the liquid pump doesn’t work.
Note
:
Please make sure that the switch of electric power is open before adding the
chemical.
There is a scale on the side of chemical tank, please add chemical liquid
according to the quantity of work.
It is strictly forbidden to spray highly acid liquid, paint and volatile menstruum.
Warning
:
Please follow the chemical menstruum recommended by the manufacturer to mix
chemical liquid, or it will harm crops and body.
Be sure to mix the chemical liquids in proper proportion in other containers. The filter must
be used when filling the chemical liquids into the chemical tank.
Please fasten the chemical cap after filling is completed.
5. Misting
Warning
: Be sure to check the battery after adding water into the chemical tank.
The liquid pump must avoid idler revolutions in order not to harm it.
Starting: