FarmBoy
™
BATTERY SPRAYERS
FB- KMB- 4165 / 4185 / 4169 / 4189 / 4180 / 4181
FB-KBS-160/161/180/181
FB-KMS-16L
: www.kisankraft.com
: info@kisankraft.com
: +91.80. 22178200
Page 21 of 28
b) Maintenance of the battery:
In the course of operation, one should understand the frequency and duration of
charge according to the actual condition and referring to usual spray frequency and
time. It’s better to charge when the battery discharged to 60%
--70%, the average
charging time is about 8 hours. Longer charging time may cause the battery to lose
water, hot and reduce the life.
Never stock the battery without power. If it h
appens so and you couldn’t recharge
the battery on time, it will easily get vitriolized to lead sulphate crystal
,
which jams
the path of the electrical ions, and make the power insufficient. Also the capacity of
the battery will get reduced. If the battery is without power for a long time, serious
damage will be caused. Therefore, even if you are not using the battery for a short
period, should charge it once in a month, so as to keep the battery in a good
situation.
It is normal that the charger is little hot while charging.
Overcharge or over discharge will reduce the life of the
battery remarkably.
Don’t connect the battery directly, or it will harm the
safety of the battery.
Never try to disassemble and assemble the battery. The battery has the protection
equipment and if you alter it, it will make the battery hot and split.
Don’t connect the anode and cathode of the battery with any metallic material.
Don’t transport battery with a metallic material, which will make the battery leak, hot
and split.
The light on the charger will turn on if you recharge immediately after charging is
over, it becomes normal. But this will result in overcharge and you should avoid the
operation.
Don’t throw the battery into the fire or heat it up, or it will make the
battery split and
electrolyte splashed.
c) Replace the fuse:
In order to protect the wire and electrical machine, this machine is equipped with a
fuse. If a blowout happens due to any reason, please unplug the right and left fixed
equipment, take out the assembly of battery, lax the packing belt, remove the battery,
open the cap of fuse to replace the damaged fuse with a new one. In addition, please
find out the cause of the blowout and find a remedy for it. After this, you could operate
it once again.
Some causes of blowout:
The charger doesn’t coincide with the battery or has any other trouble.
The pesticide got stuck to the liquid pump.
The wire is short circuited due to the damage.
Incorrect connection.