Assemble the End Frame
After the ground posts are set, assemble the remainder of
the end frame.*
• Angled Bracket (#QH1330)
• Carriage bolts and nuts and Tek screws (#FA4482B)
• QH1404 band clamps and 104074 brackets
• 2" x 2" square tube (105328) and 104075 inserts
*Refer to the End Wall diagrams for door framing and
connecting hardware.
Diagrams shown are specific to an
10' x 9' overhead door.
Complete the following steps:
1. Using the dimensions on the End Frame diagrams (or
for the doors if equipped) and the
2" x 2" square tubing
(105328)
, related hardware, and connectors, assemble
the door frame of the end wall.
NOTE:
Consult the End Frame diagram to properly
position and connect the brackets.
Diagram shows how to secure header to door jambs
using Tek screws and a QH1330 bracket at each end.
Splice the joints of the 2" x 2" tubes using a 104075
(1.75" x 1.75") square tube insert and Tek screws.
Ground Level
Door Jambs
Header
2" x 2"
1.75" x 1.75"
Insert
2" x 2"
Tek Screws
2. After the 2" x 2" door framing is installed, repeat the
steps to assemble the remaining end wall framing.
104074
Square-
to-Round
Bracket
FAH320B
Carriage Bolt
Drill 5/16"
Hole.
Diagram above shows bracket attached to the top of
door jamb.
The lower end of each 2" x 2" door jamb slides over
each 1.75" x 1.75" ground post set in concrete. Secure
the connection by installing Tek screws on the back or
inside surface of the verticals.
To avoid damaging the end panel (if equipped) or
conflicting with an overhead door installation (if
equipped) do not install Tek screws from the outside or
within the door opening.
QH1330
Bracket
Header
Tube
Overhead
Door
Extension
Door
Jamb
NOTE:
Connect and cut tubes as needed to frame the
remainder of the end wall.
3. Secure each vertical to the base rail and the base
rail to the end rafter and door jambs using a QH1330
bracket. See End Framing—Front diagram.
4. After assembling the end wall, read the special note
about the door frame that follows before installing the
end panels.
Use door to set
the correct rough
dimensions. Header
is removed to install
door then reattached.
Cut from
an 8' tube
Use 1.5" x 1.5"
tube for door.
Cut from an 8' tube
QH1330
Bracket
Header and right door
jamb are loosened or
removed to install door.