- 14 -
How to operate.
Perform the following steps after the hot water is used.
If control switch is not easily accessible :
Partially open the hot water faucet so that there is less than half gallon flow until the cold water
starts to run.
1.
Turn the ON-OFF button off.
2.
Turn on the hot water faucet.
Let the residual hot water completely run out.
Turn off
USE IN THE LIME-RICH WATER (HARD WATER) AREA
Caution
In case the unit is used in the lime-rich water (hard water) area, make sure to flush the
residual hot water away.
Otherwise lime may harden and deposit in the pipes causing low efficiency and damage to
the unit.
• Contact a qualified MPI service technician to remove lime once a year.
Failure to perform the annual maintenance will cause malfunction or damage to the heat
exchanger.
Damage caused by the lime build up is not covered by the unit's warranty.
If a “LC” code shows in the remote controller, call a technician to flush the system.
Turn on
3.
Turn off the hot water faucet when the cold
water starts to run.