- 23 -
Alarm record monitor mode
Alarm record can be monitored by special operation of remote controller
1. Start up of alarm record calling mode.
While ON/OFF button is OFF, alarm record calling mode is obtained by simultaneously
pushing both UP/DOWN buttons ( ) at Main or Bath remote controller for 5 consecutive
seconds.
• The ON indicator will flash while alarm record calling mode is ON.
2. Alarm record list indication method.
Alarm record can be monitored by pushing UP/DOWN button. ( )
Alarm occurrence order will match the following indication.
1 ---- Previous alarm (If present alarm is not reset, it shows present alarm.)
2 ---- Alarm 2 occurrences ago.
3 ---- Alarm 3 occurrences ago.
4 ---- Alarm 4 occurrences ago.
5 ---- Alarm 5 occurrences ago.
6 ---- Alarm 6 occurrences ago.
7 ---- Alarm 7 occurrences ago.
8 ---- Alarm 8 occurrences ago.
• If no alarm has been input, indicated by hyphen. (---)
3. Clearing alarm record.
During alarm record monitor mode, you can clear alarm record index, alarm record 1-8 and
combustion period during alarm by pushing ON/OFF button for 10 consecutive seconds.
• Clearing of compiled number of alarms shall not be done.
• In case the unit is relocated, be sure to use the above clearing procedure.
4. Completion of alarm record monitor mode.
• Alarm record monitor mode will be completed by simultaneously pushing both UP/DOWN
buttons ( ) for 5 consecutive seconds.
• Alarm record monitor mode will be disengaged if no further operation is made for 5 consecutive
minutes while alarm record monitor mode is ON.
• Alarm record monitor mode will be disengaged if operation is resumed by other connected
remote controller.