- 47 -
• Horizontal installation.
Horizontal installation can consist of only horizontal termination (straight termination or
L termination), reducer, and 90º elbow. If the distance between an inner wall and the center of
the appliance flue outlet is under 5.7" (146mm), use L termination [FFT-7U(L)] and reducer as
shown in Fig. 4-1. Otherwise, use straight termination [FFT-7U] and reducer as shown in
Fig. 4-2.
A continuously DOWNWARD slope of no less than 2º (1/4 in/ft) is maintained in the horizontal
portion.
• Horizontal extended installation.
Horizontal extended installation means installation on an internal wall apart from the appliance.
It can consist of straight termination, reducer, straight lengths, adjustable lengths, and elbows
as shown in Fig. 4-3. If vent system has vertically installed lengths longer than 5' (1.5m), or has
3 elbows, install drain tee direct on the appliance flue outlet and male-male adapter before
horizontal lengths as shown in Fig. 4-4. The directions of lengths are different between
Fig. 4-3 and Fig. 4-4.
A continuously DOWNWARD slope of no less than 2º (1/4 in/ft) is maintained in the horizontal
portion toward the outside.
VENT PIPE INSTALLATION
Fig. 4-2
Horizontal installation [FFT-7U]
Fig. 4-1
Horizontal installation [FFT-7U(L)]
Fig. 4-3
Horizontal extended installation without drain tee
Fig. 4-4
Horizontal extended installation with drain tee
No less than 2º (1/4 in/ft)
L termination
Reducer
No less than 2º (1/4 in/ft)
No less than 2º (1/4 in/ft)
Straight termination
Reducer
90º elbow
No less than 2º (1/4 in/ft)
Male-male adapter
Drain tee
Male end
Female end
(2) Detail of installation.