EDID Management 

The SY-UHD-S41A can handle EDID data by any one of three methods: 

1.

 

Copy the EDID from the output automatically to all inputs. 

2.

 

Use one of five embedded EDID tables, each of which can be upgraded separately. 

3.

 

Use one of ten custom EDID data tables, each of can be upgraded separately. 

The data for any of the ten custom EDID data tables must be programmed first by using the 
EDIDUpgrade[x] command before it can be used as these locations are blank by default. 

To set which of one these options the SY-UHD-S41A should use, simply set the EDID DIP switch to the 
desired setting in the following table: 

Setting 

EDID Mode 

DDDD 

Copy the output automatically to the inputs 

DDDU 

Embedded EDID 1 (default: 1080p 3D 2CH) 

DDUD 

Embedded EDID 2 (default: 1080p 3D Multichannel) 

DDUU 

Embedded EDID 3 (default: 1080p 2D 2CH) 

DUDD 

Embedded EDID 4 (default: 1080p 2D Multichannel) 

DUDU 

Embedded EDID 5 (default: 3840x2160 2D @ 30Hz) 

DUUD 

Custom EDID 1 – default state is blank 

DUUU 

Custom EDID 2 – default state is blank 

UDDD 

Custom EDID 3 – default state is blank 

UDDU 

Custom EDID 4 – default state is blank 

UDUD 

Custom EDID 5 – default state is blank 

UDUU 

Custom EDID 6 – default state is blank 

UUDD 

Custom EDID 7 – default state is blank 

UUDU 

Custom EDID 8 – default state is blank 

UUUD 

Custom EDID 9 – default state is blank 

UUUU 

Custom EDID 10 – default state is blank 

 

In the above table D means the switch is in its down state and U means it is in its up state. 

When upgrading the EDID data tables, the 

EDIDUpgrade[x].

 command should only be used from a 

serial emulation program that can send the binary EDID image after sending the appropriate 

EDIDUpgrade[x].

 command. Be sure that the binary image only contains valid EDID data block(s) to 

ensure correct interpretation of the EDID data by the HDMI source equipment. 

 

 

 

Summary of Contents for SY-UHD-S41A

Page 1: ...SY UHD S41A SY Electronics Ltd Unit 7 Worrall Street Salford Greater Manchester M5 4TH United Kingdom Tel 44 0 161 868 3450 Fax 44 0 161 868 3459 www sy co uk Installation Guide 4K HDMI 4x1 Switcher ...

Page 2: ... IR remote control for video switching RS232 control for video switching HDMI 1 4a compatible Supports 4Kx2K full 3D HDCP and CEC Connectors and Controls Front Name Description Power LED Unit powered A Indicates the audio status Green for de embedded HDMI or Yellow for ARC mode M Indicates switching mode Green for manual switching mode or Yellow for auto switching mode Input LEDs Indicates the sel...

Page 3: ... there is at least one functioning HDMI input signal To enable the auto selection mode press the SELECT button until the Auto LED lights In this mode the SY UHD S41A behaves in the following manner 1 It will automatically select to the next highest available input whenever the currently selected input source is disconnected 2 When a new HDMI signal appears at any input that input is automatically ...

Page 4: ...UU Embedded EDID 3 default 1080p 2D 2CH DUDD Embedded EDID 4 default 1080p 2D Multichannel DUDU Embedded EDID 5 default 3840x2160 2D 30Hz DUUD Custom EDID 1 default state is blank DUUU Custom EDID 2 default state is blank UDDD Custom EDID 3 default state is blank UDDU Custom EDID 4 default state is blank UDUD Custom EDID 5 default state is blank UDUU Custom EDID 6 default state is blank UUDD Custo...

Page 5: ... Set the ARC mode off ARC0 Switch Device System Notes 1 The actual response provides the current operating status of the unit giving the switching status switching mode and the ARC status for example AV spc 4 spc spc 1 cr lf AV spc 2 spc spc 2 cr lf AV spc 1 spc spc 3 cr lf AV spc 3 spc spc 4 cr lf Manual spc Switch cr lf Switch spc Device spc System cr lf 2 Auto mode is also disabled when a manua...

Page 6: ...SY UHD S41A 6 www sy co uk Figure 1 SY UHD S41A Connection Diagram ...

Page 7: ... these devices while powered please observe the following instructions 1 Use the power supplies provided If an alternate supply is required check Voltage polarity and that it has sufficient power to supply the device it is connected to 2 Do not operate either of these products outside the specified temperature and humidity range given in the above specifications 3 Ensure there is adequate ventilat...

Page 8: ... two year standard warranty beginning from the date of purchase as stated on the sales invoice Online registration of this product is required to activate the full three year extended warranty For full details please refer to our Terms and Conditions 4 SY Product warranty is automatically void under any of the following conditions The product is already outside of its warranty period Damage to the...

Reviews: