Page 1: ...ember to insert the batteries according to the markings in the battery compartment The wrong polarity can damage the weather station Damage that has occurred by careless handling is not covered by the guarantee Product Description Display of indoor and outdoor temperature wind speed wind direction humidity rainfall amounts time and date Alarm function for certain weather conditions as well as reco...

Page 2: ... Rainfall high alarm 11 lndoor temperature high alarm and low alarm 12 Temperature unit 13 lndoor temperature 14 lndoor humidity high alarm and low alarm 15 lndoor humidity 16 Rainfall unit 17 Outdoor temperature high alarm and low alarm 1 8 Outdoor temperature 19 Outdoor reception signal 20 Outdoor Humidity 21 Outdoor transmitter low battery indicator 22 Outdoor humidity high alarm and low alarm ...

Page 3: ...ill function normally The transmitter will make a data transmission which will start the radio mntrolled time reception routine lf the time signal is detected correctly the LED will start to flash 5 times and then the LED will be pn for 20s indicating that the time signal his been found conectly When the time signal is bad and reception is not possible the transmitteiwill terminate radio controlle...

Page 4: ...e resynchronized to the transmitter within 3 hours lf you want to shorten the receiving dpta time the base stati on has to re install the battery so that it can have the new security code right way however the previous weather data and alarm value settings in the receiver will be lost Nofe Commonly the radio communication between receiver and transmitter in the open field can reach a distance of u...

Page 5: ...sors Use the bubble level on the rain sensor as a guide to verify that sensors are level Program Mode The base station has five keys for easy operation SET key key HISTORY key ALARM key MIN MAX key No e When setting certain units in the manual setting mode hold the or MIN MAX key for 2 seconds will increase decrease digits in greater steps The setting procedure can be exited at any time by either ...

Page 6: ...g hours minutes Select DD MM or MM DD format Calendar setting year month date Wind speed and gust display units in km h m s bft mph knots Wind direction Rainfall display units in mm or inch Temperature display unit degree Celsius or Fahrenheit Calibration Mode Press the HISTORY key for 8 seconds while in normal mode to enter the Calibration Mode and the wind factor digits will start flashing You c...

Page 7: ...e bucket tips and records rainfall foi each 0 01 or 0 3 mm of rain To calibrate rainfall we recommend a tube type rain gauge Use a rain gauge with an aperture of at least 4 inches Any smaller and the readings obtained may not be accurate Place the tube type rain gauge directly next to the rain collector Compare the totals on three storms Based on ihis develop an average for how far off the reading...

Page 8: ...e low alarm 40 C_60 C 4 Wind chitt tow atarm 40 C 60 C 5 Dew point tow atarm 40 C 60 C 6 lndoor humidity low alarm 1 99 7 lndoor temperature low alarm 9 9 C__60 C ln the alarm modes press key or MIN MAX key to change or scroll the alarm value 9t tne key or MIN MAX key for 2 seconds will increaie decrease digits in greai steps press the ALARM key to select the alarm on or off if alarm is enabled th...

Page 9: ...or temPerature maximum 9 Wind chill temperature maximum 10 Dew point temperature maximum 11 lndoor humidity maximum 12 lndoor temPerature maximum ln the minimum reading Mode press the key to disptay the following mlnimum values together with the time and date at whiCh these values were retorded if the SET key is held down for 3 seconds in the following individual minimum values will be reset to cu...

Page 10: ...e used when the outdoor temperature is lower than 20 C because the batteries discharging capability is greatly reduced When out of the temperature range of 10 35t the transmrtteis low battery indicator may show up abnormally even if you change to new batteries because the low voltage test point will rise along with the temperature drop under 10r ln this case you do not need to change thetransmitte...

Page 11: ...How to rePlace the sensor Replacing the Rain cotlector and thermo hygro sensor ...

Page 12: ... Replacing wind sensor Before replacing the wind senso you need to unptug the cable from the rarn sensor as iltustrated ...