circumstances, +50° can only be achieved if the target is placed on the ceiling.
• Distribute the target sheets uniformly over the specified range. At least one board must be close to the horizon (0°).
• The distance between the target sheets and the scanner must be between 1.5 m to 3 m.
• All target sheets must be vertically aligned.
Laser Scanner Placement
• Mount the laser scanner on a tripod.
• Place tripod and scanner on stable, flat surface. The tripod must not move during scanning.
• Keep the distance between the target sheet and the scanner between 1.5m to 3m.
• Adjust the tripod to keep the scanner horizontal.
• Either 0° or 180 ° directions can be used for the horizontal rotation direction toward the target.
Site location example:
- Distance between target and scanner: 1.7m
- Scanner installation height: 1.12m
- Target top height: 2.2m
Scan & Compensate
Compensate with SCENE according to the
and execute scanning and correction. When the
Compensation is completed, " Compensation report" is displayed together with the Compensation result.
• Select whether you want to apply the compensation data to the scanner.
• Click disconnect to disconnect from scanner and finish the On-Site compensation.
Updated: Fri, 04 Sep 2020 19:09:50 GMT