Chapter 10: Technical Data
10.8 Deflection unit
10.9 Ambient Conditions
10.10 Notes
1
Ranging error is defined as a systematic measurement error at around 10 m and 25 m,
one sigma.
2
Ranging noise is defined as a standard deviation of values about the best-fit plane for
measurement speed of 122,000 points/sec.
3
A noise-compression algorithm may be activated thereby compressing raw data noise
by a factor of 2 or 4. Subject to change without prior notice.
4
Ferromagnetic objects can disturb the earth magnetic field and lead to inaccurate
measurements.
5
2x150° - Homogeneous point spacing is not guaranteed.
Field of view:
(vertical/horizontal): 300°
5
/ 360°
Step size:
(vertical/horizontal):0.009° (40,960 3D-Pixel
on 360°) / 0.009°
(40,960 3D-Pixel on 360°)
Max. vertical scan speed:
5,820 rpm or 97 Hz
Ambient Temperature:
5 °C - 40 °C
Extended operating
temperature:
-20 - 55°C
Low temperature operation: the scanner
must be powered on while internal tempera-
ture is at or above 15 °C
High temperature operation: additional
accessory required, further information on
request.
Humidity:
Non-condensing
Altitude:
< 2000 m
Summary of Contents for FocusM 70
Page 6: ...FARO Laser Scanner Manual 1...
Page 12: ...FARO Laser Scanner Manual 7...
Page 58: ...FARO Laser Scanner Manual 53...
Page 132: ...FARO Laser Scanner Manual 127...
Page 146: ...FARO Laser Scanner Manual 141...
Page 156: ...FARO Laser Scanner Manual 151 Chapter 12 Disposal Figure 12 114 WEEE Symbol...
Page 166: ...FARO Laser Scanner FocusS Manual 161...
Page 170: ...FARO Laser Scanner Manual 165...
Page 172: ...FARO Laser Scanner Manual 167...
Page 193: ...Appendix F Certifications...
Page 194: ...F 1 CE Conformity...