Environment
】
1.
Motionless metal objects
Leave minimum 50cm between your WTMD and big metal objects. False
alarm will be caused when WTMD be shake accidentally.
2.
Not rigid or stable floor
Position and fix WTMD on a flat, stable floor. False alarms may be caused by
shaking the equipment.
3.
Movable metal objects
Leave minimum 1~2m between your WTMD and big movable metal object.
False alarm will be caused when big metal object move at the nearby place.
Especially Rolling grilles and closures, iron burglarproof door, folding
reticulated iron gate.
4.
EMR and EMI
Far from the EMR and EMI. Recommend distance is 1~2m
List of EMR and EMI as followed:
electrical apparatus control system, radio frequency apparatus, computer
utility and peripheral device, video monitor, high-power machine, high
power transformer, AC power line, thyristor control circuit, high power
switch, inverter welding machine, engine, motor machine, daylight lamp
with rectifier
5.
Position WTMDs side by side
When posit WTMDs side by side, the device will be influenced each other to
some extent. Please maintain the distance between every two devices not less
than 50cm.
6.
Do not fix the device in a high wind place, avoid emitting false signal.
【
Assembling & Mounting
】
1.
Unpack the packages of Main Control and Left, Right Side Panel.
2.
Arrange the major components as shown. Put Main Control unit faceup. Put
the spare parts bag aside.
3.
Left and Right Side Panel should be perpendicular to the main control unit.
Use the key open the Main Control unit. Screw two side panels to Control Unit
by 8 fixing screws and Allen Key.
4.
Connect the aviation plugs in the main control box to the aviation sockets on
the left detect panel and right detect panel.
5.
Connect the power plug to the power supply socket on the either detect panel
according to the specific position of power supply. Connect 220VAC
operational power supply.