TROUBLE SHOOTING
CAUTION :
In case of unexpected failure, electrically insulate the machine by means of an
omni polar disconnection device.
TURNTABLE NOT TURNING :
.
Feeding plug not connected or defective:
- check the plug
Machine not powered:
- Restore the electric connections.
Defective inverter :
- replace the inverter, (skilled staff needed in this case)
Motor shorted:
- replace the motor, (skilled staff needed in this case)
Belt broken:
- Replace the belt
ROTATION CONTROL PEDAL FAILS TO RETURN TO CENTRAL POSITION:
.
Control spring broken:
- Replace the control spring.
BEAD BREAKER PEDAL AND TABLE TOP PEDAL DO NOT RETURN TO HOME POSITION :
.
Control spring broken:
- Renew the spring.
No oil in lubricator:
- Top up lubricator with SAE20 non-detergent oil .
AIR LEACK INSIDE THE MACHINE :
.
Air leak from bead breaker cock:
- Renew the cock.
- Renew bead breaker cylinder.
Air leak from the table top cock:
- Renew table cock unions.
- Replace the cock.
BEAD BREAKER CYLINDER LACKS FORCE, FAILS TO BREAK BEADS AND LEAKS AIR :
.
Silencer plugged::
- Renew silencer.
Cylinder seals worn:
- Renew seals.
- Renew bead breaker cylinder.
23
BEAD BREAKER CYLINER LEAKS AIR AROUND THE ROD :
.
Air gaskets worn:
- Replace gaskets.
- Replace bead breaker cylinder.
Summary of Contents for RASE.2234
Page 13: ...DECALCOMANIE 1 2 3 4 10 11 12 13 15 16 17 14 9 8 7 6 5 9 10 13...
Page 36: ...LABELS 1 2 3 4 10 11 12 13 15 16 17 14 9 8 7 6 5 9 10 13...
Page 48: ...SCHEMA ELETTRICO 220 V 1 ph 50 Hz 1 speed 25 SCHEMA ELETTRICO 400 V 3 ph 50 Hz 1 speed...