MAINTENANCE
The reg lubricator is equipped with a semiautomatic condensation drain device.
This device operates whenever the compressed air supply to the machine is cut off. Drain the
condensation manually fig. 27 when the level exceeds the mark L , fig. 27.
L
27
Clean the top plate of the turntable every week: remove any
accumulated dirt and clean with environmentally-friendly sol-
vents.
Monthly checks:
Clean and lubricate, with environmentally-friendly solvents
only, the arms of the tool-carrying head and the bead brea-
king unit and relevant sliding screws.
Check the oil level in the air lubricator and, if necessary, top
up with non-detergent SAE20 oil to the indicated level L1
see fig. 28.
Clean with a dry cloth. Avoid contact with solvents.
Check the oil flow-rate through the transparent cover
(correct flow-rate: 1 drop of oil every 4 bead breaking
cycles). Adjust if necessary but turning the set screw fig. 29.
CAUTION:
Keep the working area clean.
Never use compressed air, jets of water or solvent to remove dirt or deposits off the
machine. When cleaning, take care not to create and raise dust as far as possible.
22
+ -
29
Oil in
L
28
AVVERTENZA :
Regularly clean the self-centering plate using special materials, non-corrosive.
Regularly grease the endless screw of the bead breaker arm.
Summary of Contents for RASE.TOP.2248
Page 13: ...DECALCOMANIE 13 9 10 1 2 3 4 9 23 8 5 6 10 11 12 13 18 14 15 16 17 17 19 20 21 22 7...
Page 38: ...LABELS 13 9 10 1 2 3 4 9 23 8 5 6 10 11 12 13 18 14 15 16 17 17 19 20 21 22 7...
Page 52: ...SCHEMA ELETTRICO ELECTRIC SCHEME 27 S 40 2 P...
Page 53: ...28 SCHEMA ELETTRICO ELECTRIC SCHEME S 40 2 P...
Page 54: ...SCHEMA ELETTRICO ELECTRIC SCHEME S 40 2 E 29...