Original notice – User’s manual
36
The pressure
of the tank is
not the desired
one.
Gauge defective.
Contact us.
Pipes or fittings in poor condition
(leaks, cracks...).
Tighten all hoses.
Replace defective hoses.
Reattach the fittings.
Check that the purge valve is closed. Close the valve.
Block air filter clogged.
Clean or change the filter.
Pilot relay defective.
Contact us.
Block defective.
Contact us.
The outlet
pressure of the
reels is not the
desired or is at
zero.
Inlet valve of FRL.
Open the valve.
FRL adjustment.
Set the FRL regulator to the desired
pressure.
Problem
connections
(leaks,
cracks...).
Replace
defective
hose
connections.
Problem with the reels.
Contact us.
The pressure
of the tank
goes down
while you are
not using air.
Pipes or fittings in poor condition
(leaks, cracks...).
Tighten all hoses.
Replace defective hoses.
Reattach the fittings.
Tank conditions.
Contact us.
Check that the purge valve is closed. Close the valve.
Non-return valve.
Contact us.
Safety valve defective.
Contact us.
Pilot relay defective.
Contact us.
The voltage at
the electrical
outlets is zero
or not the
correct.
Engine-generator belt.
Contact us.
Engine speed incorrectly set.
Contact us.
Differential switch on "OFF".
Switch the differential switch on
“ON”.
Outlet connection.
Connect the plugs correctly.
Cables defective.
Contact us.
Generator defective.
Contact us.
The
compressor
does not stop
inflating.
Pipes or fittings in poor condition
(leaks, cracks...).
Tighten all hoses.
Replace defective hoses.
Reattach the fittings.
Block defective.
Contact us.
In case of a persistent problem, do not use the device and call us. All operations
on the electrical installation and on the mains supply must be done by qualified
and authorized personnel. Any damage resulting from the non-observance of
these recommendations resulting in the end of guarantee.