Emergency manual pump
1. Remove the oil tank cap
A
.
2. Remove fitting
B
at the end of the rilsan hose from
the pump and immerse the hose in the oil tank.
3. Open the emergency valve
C
.
4. Remove the emergency fitting
D
from its support.
5. Remove the plug of the solenoid valve concerned by
the desired movement.
6. Tighten the emergency fitting to the same solenoid
valve.
7. Pump using the manual emergency pump.
8. Do not use the device until it has been repaired.
E
: Solenoid valves “mandrel”
F
: Solenoid valves "translation"
G
: Solenoid valves "folding/unfolding"
H
: Solenoid valves "mandrel holder"
Side "1 ring": opening solenoid valve
Side "2 rings": closing solenoid valve
D
E
B
A
F
G
H