36
15
TROUBLE SHOOTING
PROBLEM
After having turned the main switch ON,
on the power pack, the general warning
light doesn’t light on and commands do
not work.
CAUSE
1) the power plug is not inserted
2) no power from the mains electric supply
1) plug in correctly
2) reset the mains electric
supply
REMEDY
After having turned the main switch ON,
the general warning light lights on but
the motor on the hydraulic power pack
doesn’t work.
C
AUSE
1) the magneto-thermal switch
is engaged
1)
call for technical aid to find out the
problem and restore the machine
functioning
ATTENTION!
Dispose of the used oil
according to the national laws
in force.
ATTENTION: if, in spite of the above
mentioned indications, the tyre-changer
does not work properly, DO NOT USE it
and call for technical assistance.
There’s a slowing down of the tyre-
changer’s movements, as well as too
poor power.
CAUSE
Oil in power pack is below minimum level
Consult paragraph “MAINTENANCE” and fill
the tank with new oil
PROBLEM
PROBLEM
REMEDY
REMEDY