Fasep 2000 srl
Rev. 1.6
Videotronic V548.G4: User’s Manual
15 April 2019
13
Fig. 56
: Distance
Fig. 57
: Width
7
MEASUREMENT AND CORRECTION OF UNBALANCE
7.1
Placing the wheel rim on the wheel balancer
7.1.1
Select the cone or flange suitable for the wheel to be balanced. Specific mounting instructions are delivered with each
flange
NOTE:
the operation of centering and tightening of the wheel on the flanges is of basic importance for correct
balancing. Good results depend on proper performance of these procedures.
To accurately clean up the superficial ones of connection before whichever operation.
!
CAUTION:
Always make sure flanges are correctly locked on the motor shaft and wheel is correctly locked on
the flange being used.
7.2
Input of Rim Dimensions (external measuring system version)
for V65x, V64x, V55x-D (automatic input of all data)
MAIN MENU
Insert the distance (fig.55).
Insert the width (fig.56).