Fasep 2000 srl
Rev. 1.3
Videotronic V653.G2: User’s Manual
02 april 2010
2-1
2
INSTALLATION
2.1
Moving the unit
WARNING
When the unit has to be moved: never lift
balancer by motor shaft or by neighborhood of it.
2.2
Assembling the unit
For ease of transportation, the wheel balancer might be disassembled
into units. If necessary, assembling instruction are provided within
each package..
2.3
Installation
The wheel balancer must be installed on a firm and level ground.
NOTE
:
the machine must be secured to the floor. Using four holes
in the base and anchor bolts provided
2.4
Electrical Hookup
!
CAUTION:
Failure to follow these instructions can results in
damage to unit or create an electrical hazard and
will void warranty..
2.4.1
Electrical hookup is to be provided by a qualified electrician.
2.4.2
A fusible wall-mounted switchbox is required at the installation site. This switch should provide on-off control and overload
protection for your wheel balancer only. The switchbox should be fused with time-delay fuse(s) in accordance with the
power rating specified on your wheel balancer.
2.4.3
Electrical connection of the machine should be by plug connectors.
2.4.4
The balancer must be effectively connected to ground. The electric cord is regularly provided with a ground terminal.
2.4.5
Make sure that Power Rate Specifications for your wheel balancer (refer to nameplate on the wheel balancer) comply
with those provided by the external power source.
!
CAUTION
After electrical hookup has been performed unit is ready to operate. Always observe pertinent safety
precautions when operating the unit (see Appendix tables for an overview of relevant Safety
requirement).
2.5
Compressed air Hookup (PL models only)
!
CAUTION
Failure to follow these instructions can result in damage to unit or create a hazard and will void
warranty.
1.
Compressed Air hookup is to be provided by a qualified technician, under the local safety
requirements, in line with relevant national standards and regulations. All fitting and hoses must
conform to local codes.
2.
A wall-mounted lubricator and water-separator is required at the installation site.
3.
Compressed Air circuit to the balancer shall be regulated to a maximum pressure of 7 atm.
Overpressure could compromise cylinder operation.
2.5.1
CONNECT TO AIR SUPPLY:
The machine is fitted with a universal connector and therefore no other special or additional fitting is required. Push all
the way onto the connector a high pressure rubber air-hose and secure it.