STORAGE AND WINTERIZING
PAGE 76
Winterizing Foam Row Marker
1. Completely flush the tank with warm
water.
2. Turn on machine and allow to operate
until no foam is generated.
3. Add anti-freezing solution such as
windshield washer solvent to tank.
4. Turn on machine until anti-freezing
solution reaches the foamheads.
5. Check the airlines and liquid lines for
holes and replace as required. Be sure
to flush, then drain, all liquid from the
system prior to storage in freezing tem-
peratures.
Removing from Storage
When removing from storage and prepar-
ing to use follow this procedure:
1. Remove the tarpaulin if it was used for
storage.
2. Check tank for cracks or damage
3. Check tank straps and hold down hard-
ware.
See “Fill the Tank”
4. Tighten all hardware.
5. Check all sprayer and hydraulic lines,
fittings and connections. Tighten as
required.
6. Lubricate grease fittings.
See “LUBRI-
CATION”
7. Replace any defective parts.
8. Drain and rinse anti-freeze from tank.
See “Drain and Rinse the Tank”
9. Calibrate the pump, nozzles and
sprayer before using.
See “SPRAYER
CALIBRATION”
10. Complete the pre-operation checklist
before using.
See “Pre-Operation
Checklist”
Clear the area of bystanders.
Remove foreign objects from the
machine and working area.
Summary of Contents for UT3P
Page 1: ...820037 FAST UT3P Sprayer 9 20 2018 FAST UT3P Sprayer OPERATION AND MAINTENANCE MANUAL...
Page 2: ...820037 FAST UT3P Sprayer 9 20 2018...
Page 5: ...UT3P DELIVERY INSPECTION CHECKLIST PAGE 2 This page intentionally left blank...
Page 19: ...MAJOR COMPONENTS PAGE 16 This page intentionally left blank...
Page 45: ...OPERATION PAGE 42 This page intentionally left blank...
Page 61: ...PAGE 58 This page intentionally left blank...
Page 83: ...820037 9 20 2018...
Page 84: ...820037 9 20 2018...