PREPARING THE MACHINE
PREPARING THE MACHINE
Utility Sprayer 25' / 30' / 40' / 45'
Page 44
6.
Attach the hose to the section valves.
a.
Loosen the clamp.
b.
Slide the hose onto the
section valve fitting. Use one
hand to support the fitting as
shown.
c.
Tighten the clamp.
7.
Attach the
Utility Sprayer to the
tractor.
8.
Connect the PTO Pump.
9.
for any additional instructions.
If
the hoses are
too long
:
1.
Disconnect the PTO Pump from the
tractor.
2.
Disconnect the hoses from the PTO
Pump.
3.
Cut hoses to the length needed to fit
the tractor.
4.
Reconnect the hoses to the PTO
Pump.
Set the (Optional) Hydraulic Motor
Driven Chemical Pump
1.
Install and tighten the drain plug at
the bottom of the pump.
2.
Set the hydraulic outlet flow to 2.8
GPM – 4.8 GPM for optimal pump
output. Reference the following
Performance Chart if needed.
Unpack the Spray Wand
The spray wand is zip-tied to the spray wand
holder for shipping. Carefully cut the ties to
release it.
NOTE: The electrical harness for
the taillight is also zip-tied to the
spray wand holder. Only cut the
ties holding the spray wand hose.