www.fastech.co.kr
Control I/O signal
38
6-4.
Output signal
1) Compare Out/Trigger Pulse Output
「
Trigger Pulse Output
」
signal is displayed when specific conditions are performed. It is
fixed to CN1 connector’s
「
COMP
」
(Compare Out) pin. And it is available when the motor
needs to be synchronously controlled by an external controller.
(For more information, refer to
’9-5.Trigger Pulse Output’
)
2) Inposition Output
After the motor stop in target position exactly on Servo ON status, the signal becomes
[ON]. The condition of this signal depends on parameter ‘Position Loop Gain’ and ‘Inpos
Value’.
* Time delay of Output signal depends on the parameter ‘Inpos’ Value’:
3) Alarm
When the motor operates normally,
「
Alarm
」
output becomes [OFF]. When the protective
function operates, alarm output becomes [ON]. The upper controller being used by the user
detects this alarm and then stops motor operation command. If overload or overcurrent
occurs while the motor is operating, the drive detects it and cuts off the motor’s current, In
addition, alarm output is turned on and
「
Alarm LED
」
flashes to indicate the type of alarm
occurrence.
4) PT ACK and PT End Output
「
PT ACK
」
and
「
PT End
」
signals are available only when the motion is executed by
position table. When motion start, PT ACK signal is set to [ON] and PT End signal is set to
[OFF]. And if all of motion loops are finished, PT ACK signal becomes [OFF] and PT End
signal becomes [ON]. If the ‘Wait time’ value in PT item is not 0, the defined time is
needed to PT End signal becomes [ON].
Refer to
「
Ezi-SERVO Plus-R User Manual – ‘Position Table Function’
」
.
Value
Mode
Description
0~63
Fast mode
Output the signal within 1[msec] after the motor stop in
target position.
64~127 Accurate mode
Output the signal within 100[msec] after the motor stop in
target position.
(The step is needed to check find exact positioning)
Jog command
Inposition signal
Summary of Contents for Ezi-Servo II Plus-E 20 Series
Page 1: ... Rev 04 User Manual Text ...
Page 10: ...www fastech co kr Specifications size of the Motor 10 ...
Page 11: ...www fastech co kr 11 Specifications size of the Motor 3 2 Motor Size ...
Page 12: ...www fastech co kr Specifications size of the Motor 12 ...
Page 18: ...www fastech co kr Configuration 18 2 86 mm motor drive ...
Page 20: ...www fastech co kr Configuration 20 2 86 mm motor drive ...
Page 74: ...www fastech co kr Appendix 74 12 3 Brake Installed Motor Specifications and Size ...
Page 76: ...www fastech co kr Appendix 76 2 Gearbox for 56mm Motor Specifications ...
Page 77: ...www fastech co kr 3 Gearbox for 60mm Motor Specifications ...
Page 78: ...www fastech co kr Appendix 78 4 Gearbox for 86mm Motor Specifications ...
Page 79: ...www fastech co kr 5 42mm motor size with Gearbox ...
Page 80: ...www fastech co kr Appendix 80 6 56mm motor size with Gearbox ...
Page 81: ...www fastech co kr 7 60mm motor size with Gearbox ...
Page 82: ...www fastech co kr Appendix 82 8 86mm motor size with Gearbox ...