⑥
Additional next step is needed as below diagram.
Fig 10.6.2
The
‘Stop’ command must be executed
before next motion command.
(In Stop mode, it does not need to ‘stop’ when there is no shock in mechanism.)
At this 'stop’ procedure, the motor move to backward as much as the ‘Push mode’
parameter values. This motion will reduce the shock in mechanism. So, if the Stop
command is not used, ‘Backward motion’ is also not executed. ‘Backward motion’
speed is set to 5000[pps] at this moment.
⑦
Time delay can be needed for shock ease till position return after stop. It depends on
mechanical conditions.
⑧
Return to start position.
(3) Control Method
This function is working only in absolute position value. The position error can be
happened due to the work status in push mode. Push motion command can be
executed by 2 methods. One is RS-485 communication (DLL library) method and the
other is external digital signal(PT Start command) method.
①
DLL library command
The following table shows the control conditions and for more information, refer to
「
User Manual – Communication Function
」
.
Also, we provide a control command that can check the status of push motion
command. The position values of using for Push Motion
are all absolute coordinate
values
.
Non-stop mode :
It must be executed the ‘Stop’ command before
next motion command
in the work detect situation.
If a shock occurs to the structure when returning to the position, it
takes
a certain delay time
to relieve the impact.
Caution
Caution
Summary of Contents for Ezi-Servo II Plus-E 20 Series
Page 1: ... Rev 04 User Manual Text ...
Page 10: ...www fastech co kr Specifications size of the Motor 10 ...
Page 11: ...www fastech co kr 11 Specifications size of the Motor 3 2 Motor Size ...
Page 12: ...www fastech co kr Specifications size of the Motor 12 ...
Page 18: ...www fastech co kr Configuration 18 2 86 mm motor drive ...
Page 20: ...www fastech co kr Configuration 20 2 86 mm motor drive ...
Page 74: ...www fastech co kr Appendix 74 12 3 Brake Installed Motor Specifications and Size ...
Page 76: ...www fastech co kr Appendix 76 2 Gearbox for 56mm Motor Specifications ...
Page 77: ...www fastech co kr 3 Gearbox for 60mm Motor Specifications ...
Page 78: ...www fastech co kr Appendix 78 4 Gearbox for 86mm Motor Specifications ...
Page 79: ...www fastech co kr 5 42mm motor size with Gearbox ...
Page 80: ...www fastech co kr Appendix 80 6 56mm motor size with Gearbox ...
Page 81: ...www fastech co kr 7 60mm motor size with Gearbox ...
Page 82: ...www fastech co kr Appendix 82 8 86mm motor size with Gearbox ...