www.fastech.co.kr
41
Operation
7.
Operation
7-1.
Power Supply Timing
The power supply of Ezi-SERVO
Ⅱ
Plus-E is supplied to the motor through the drive module.
Therefore, before supplying power, connect the cable between the drive and the motor, and
then supply power to the drive module.
The default setting of Ezi-SERVO
Ⅱ
Plus-E after power supply is Servo OFF.
7-2.
Servo ON Operation
After power is supplied, set the drive module to Servo ON as follows.
Click
「
SERVO ON
」
button at the User Program(GUI).
Give a command through communication by using DLL library.
Assign
「
Servo ON
」
to control input pin, and supply signal through the pin.
After Servo ON command is given, In-position is finished to the time as shown below.
t1 can be different subject to the rising time of supplying power and motor status.
7-3.
Operation Mode
This drive can do three control operations such as I/O command, communication command
(DLL program), and User Program (GUI).
(1) I/O Command Mode
This drive can execute control operation like in-position by I/O command transmitted from
the upper controller. The in-position control operation is executed by operating position
table with I/O command.
(2) Communication Command Mode
This drive can execute control operation like in-position by communication command from
the upper controller. Also, it can operate using a position table among communication
commands.
Position Table Operation Sequence
It is can executed continuous operation by position table at the I/O command mode.
①
By using PT A0 ~ PT A7 input signal or DLL program, set PT number to be operated.
②
In case of Servo OFF, set the drive to Servo ON by communication program or Servo
ON control input.
If the Servo ON signal is assigned to control input, Servo ON
command from User Program(GUI) or DLL Library will not be
executed.
Servo ON command
t1
In-Position
Caution
Summary of Contents for Ezi-Servo II Plus-E 20 Series
Page 1: ... Rev 04 User Manual Text ...
Page 10: ...www fastech co kr Specifications size of the Motor 10 ...
Page 11: ...www fastech co kr 11 Specifications size of the Motor 3 2 Motor Size ...
Page 12: ...www fastech co kr Specifications size of the Motor 12 ...
Page 18: ...www fastech co kr Configuration 18 2 86 mm motor drive ...
Page 20: ...www fastech co kr Configuration 20 2 86 mm motor drive ...
Page 74: ...www fastech co kr Appendix 74 12 3 Brake Installed Motor Specifications and Size ...
Page 76: ...www fastech co kr Appendix 76 2 Gearbox for 56mm Motor Specifications ...
Page 77: ...www fastech co kr 3 Gearbox for 60mm Motor Specifications ...
Page 78: ...www fastech co kr Appendix 78 4 Gearbox for 86mm Motor Specifications ...
Page 79: ...www fastech co kr 5 42mm motor size with Gearbox ...
Page 80: ...www fastech co kr Appendix 80 6 56mm motor size with Gearbox ...
Page 81: ...www fastech co kr 7 60mm motor size with Gearbox ...
Page 82: ...www fastech co kr Appendix 82 8 86mm motor size with Gearbox ...