-7-
Use a connection cable (Option) when extending the wiring distance the motor
and drive.
Prevent leakage current
Stray capacitance exists between the drive’s cable and other cables, the earth
and the motor, respectively. A high-frequency current may leak out through
such capacitance having a determental effect on the surrounding equipment.
The actual leakage current depends on the drive’s switching, the length of
wiring between the drive and motor, and so on. When connecting and earth
leaksge breaker, use the products offering resistance against high frequency
current.
Warning
Before connecting cables, check if input power is off
Otherwise, an electric shock or a fire may occur.
The case of this Ezi-SPEED is installed from the ground of the internal
circuit by the condenser. Please Ground the Ezi-SPEED.
Otherwise, an electric shock or a fire may occur and a cause of malfunction of
machine.
• Operating and setting change
Attention
If a protection function (Alarm) occurs, firstly remove its cause and then
release (Alarm reset) the protection function.
If you operate continuously without removing its cause, the machine may get
damaged or the user may get injured.
Do not change free input to ON during motor operated
Motor will be stop and holding power will be lost. The machine may get
damaged or the user may get injured.
Make all input signals to OFF before supply input voltage to Ezi-SPEED
drive.
The machine may get damaged or the user may get injured by motor
operation.
All parameter values are set by default factory setting value. Change this
value after reading this manual thoroughly.
Otherwise, the machine may get damaged or other kinds of accidents may occ
Summary of Contents for Ezi-SPEED ESD-30-C
Page 1: ......
Page 9: ...9 2 Characteristics 2 1 Part number...
Page 15: ...15 3 2 Dimensions 30W 60W 120W Drive 200W 400W Drive...
Page 18: ...18 ESM 90 H 120 ESM 104 H 200 ESM 104 H 400...
Page 19: ...19 4 3 Characteristics of motor torque 30W 60W 120W...
Page 20: ...20 200W 400W...
Page 63: ...63 8 2 Setting and 7 segments display 1 Monitor mode...
Page 64: ...64 2 Input Output setting mode...
Page 65: ...65 3 Parameter setting mode 1page...
Page 66: ...66 3 Parameter setting mode 2page...
Page 67: ...67 3 Parameter setting mode 3page...
Page 68: ...68 3 Parameter setting mode 4page...
Page 69: ...69 4 NVM saving mode...