-78-
•
Motor operation
If the acceleration time and deceleration time are set shorter then 0.5 seconds, the motor takes
for a longer time than setting time. If they are setting approximaterly 0.5 seconds or more, the
motor can accelerate and decelerate in the setting time. (With no load)
8.7 Setting of torque limit
Torque limit can be set via parameters. Factory setting is 300% and can be set from 10% to 300%
8.8 Lock of setting data
Press and hold the “S” button, can be lock of setting data. If the setting data is locked, the data
can not be changed until the lock is released.
8.9 Limiting the setting range of the rotation speed
The setting range of the rotation speed is set to 50 to 4000rpm at the time of shipment. This
setting range can be changed to limt
Rotation speed
Acceleration time
Setting time
Actual motor operation
Time