background image

 

OPERATING INSTRUCTIONS/MAIN SEAL REPLACEMENT 
Page 1 of 2 

 

 

    www.fastestinc.com 

    Roseville, MN 
    Ph 1-800-444-2373 

 

 

    Fax 651-645-7390 

 

 

    WP095   Rev C   5/5/2021 

     

MET / METH TWISTMATE Series Connectors 

DESCRIPTION:

 

Manual Twist Connection Tool for Sealing External Threads.

 

 
 
 
 
 
 
 
 
 

 
 
 
 

Please thoroughly read the instructions prior to operating the connector. The                  
Connectors are designed to provide a safe, reliable leak-tight seal and connection when properly 
maintained and operated.   

 

The connector is designed to mate with a specific application.  Verify the application prior 

to the introduction of pressure or processing. Use only in a safe environment. Safety chains 
and guards are recommended for all applications. 

 

Connectors are NOT designed for permanent connections and are for temporary 

connections only. Inadvertent loosening and loss of media may result when used as a 
permanent connection. 

 

Connectors are not internally valved and will not prevent loss of media when disconnected. 

 

DO NOT EXCEED pressure rating as marked on connector or corresponding literature. 

Operating pressure rating based on tests using NPTF threads to (SAE J476a Dryseal 
Specifications) of cold drawn steel. Material or thread deviations may reduce working 
pressure and should be verified by test. 

 

  Installation 

  Operation 

  Main Seal Replacement 

  Connector Maintenance 

  Safety Warnings - Guidelines 

 
 
 

INSTALLATION:

 

1.  This applies to the flow through version only.

 

2. 

CAP STYLE CONNECTORS DO NOT REQUIRE ANY INSTALLATION, 
THEY ARE SIMPLY A CAP. 

3.  Connect media hose/fitting to the termination end (most MET’s are male 

some are female) on connector. 

a. 

Pipe tape and or thread sealant is recommended. 

b. 

See chart below for termination torque ratings. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

OPERATION: 

1.  Thread Twistmate connector finger-tight onto test piece until main seal 

contacts test piece. This applies to both versions.

 

2. 

DO NOT WRENCH TIGHTEN!!! 

 
 
 
 
 
 
 
 
 

Termination Port Size 

Torque lbs-ft 

1/8 NPT 

12 

1/4 NPT 

21 

3/8 NPT 

28 

1/2 NPT 

35 

3/4 NPT 

46 

1 NPT 

90 

1-1/4 NPT 

150 

1-1/2 NPT 

200 

MET FLOW VERSION 

CONNECTOR 

MET CAP VERSION 

CONNECTOR 

TERMINATION 

CONNECTION (M) 

MAIN SEAL INSIDE 

CONNECTOR 

Reviews: