70
FASTORA DAS-208CC Disk Array
4.7 Rebuilding a Failed Disk Drive
If you have a spare drive on the system, the controller will rebuild the disk array
automatically. Select the “Utilities” function from main menu.
9 Utilities
93 Add Drive
Select the “Add Drive” option, press
Enter
and specify which slot has a newly
installed disk drive. FASTORA DAS-208CC Disk Array has all the slots
numbered on the front panel (HD1 – HD8).
For example, the forth slot has a new disk.
93 Add Drive
4
Select the “95 Rebuild Drive” option from sub-menu.
9 Utilities
95 Rebuild Drive
Press
Enter
and select ‘YES’ option to begin the rebuild process.
Summary of Contents for DAS-208CC
Page 1: ...FASTORA DAS 208CC Disk Array User Guide For Ultra160 to Ultra160 RAID Subsystem V 1 0a ...
Page 23: ...23 FASTORA DAS 208CC Disk Array 3 4 1 Hierarchical Structure of Main Menu ...
Page 28: ...28 FASTORA DAS 208CC Disk Array 249 Partition 4 24A Del RAID Set To delete the RAID set ...