Functional Description
VIM301
V I M 3 0 1 U s e r M a n u a l
31
© 2 0 1 5 F a s t w e l v . 0 0 2
3.2.14
Auxiliary Power Connector
The module itself uses only +5 V power voltage. +12 V circuit is connected to the appropriate
contacts of the following connectors: XS1 (PCI/104), XS2 (PC104), XP1 (power), XP4 (EL display),
and XP11 (video cameras). +12 V voltage is not used by the module, it is intended to power a
Planar EL display (for VIM30104 and VIM30105 versions) and video cameras connected to XP11
header (for VIM30103 and VIM30105 versions). If a PC/104 or PC/104-Plus power supply unit is
installed in the stack, the module is powered via PC/104-
Plus connectors’ contacts.
The auxiliary power connector (XP1) is optional, it is not installed on basic versions of VIM301.
XP1 connector type is AMP 4-171826-4. Recommended mating connector is AMP 171822-4, with
AMP 170262-1 contacts set or other contacts appropriate to 171822-4 (AMP) connector type.
Please, find details on manufacturer’s web site: www.tycoelectronics.com
Table 3.16:
XP1 Connector Pinout
Contact
Signal
1
+5V
2
GND
3
GND
4
+12V
For stable operation of the module a power supply unit should p5 V ±5% and not less than
0.5 A current.
Figure 3.16:
XP1 Connector