Functional Description 

 

VIM301 

V I M 3 0 1   U s e r   M a n u a l

 

27 

© 2 0 1 5   F a s t w e l     v . 0 0 2

 

3.2.12 

PCI/104 Connector (PCI bus) 

PCI/104 connector (XS1) allows installation of VIM301 into a PC/104-Plus stack and connection of 
PCI buses of graphics controller and a processor module. The PCI bus controller of VIM301 
conforms to PCI 2.1 specification. The connector mounted on VIM301 is AMP 1375799-1. 

The pinout of XS1 connector is presented in the table below. 

Table 3.14: 

XS1 Connector Pinout  

Contact 

Signal 

In/Out 

Contact 

Signal 

In/Out 

A1 

GND 

Power 

B1 

– 

– 

A2 

– 

– 

B2 

AD2 

In/Out 

A3 

AD5 

In/Out 

B3 

GND 

Power 

A4 

C/BE0# 

In/Out 

B4 

AD7 

In/Out 

A5 

GND 

Power 

B5 

AD9 

In/Out 

A6 

AD11 

In/Out 

B6 

– 

– 

A7 

AD14 

In/Out 

B7 

AD13 

In/Out 

A8 

– 

– 

B8 

C/BE1# 

In/Out 

A9 

– 

– 

B9 

GND 

Power 

A10 

GND 

Power 

B10 

– 

– 

A11 

STOP# 

In/Out 

B11 

– 

– 

A12 

– 

– 

B12 

TRDY# 

In/Out 

A13 

FRAME# 

In/Out 

B13 

GND 

 

A14 

GND 

Power 

B14 

AD16 

In/Out 

A15 

AD18 

In/Out 

B15 

– 

– 

A16 

AD21 

In/Out 

B16 

AD20 

In/Out 

A17 

– 

– 

B17 

AD23 

In/Out 

A18 

IDSEL0 

In 

B18 

GND 

Power 

A19 

AD24 

In/Out 

B19 

C/BE3# 

In/Out 

A20 

GND 

Power 

B20 

AD26 

In/Out 

A21 

AD29 

In/Out 

B21 

+5V 

Power 

A22 

+5V 

Power 

B22 

AD30 

In/Out 

A23 

REQ0# 

Out 

B23 

GND 

Power 

A24 

GND 

Power 

B24 

REQ2# 

Out 

A25 

GNT1 

In 

B25 

– 

– 

A26 

+5V 

Power 

B26 

CLK0 

In 

A27 

CLK2 

In 

B27 

+5V 

Power 

A28 

GND 

Power 

B28 

INTD# 

Out 

A29 

+12V 

Power 

B29 

INTA# 

Out 

A30 

– 

– 

B30 

REQ3# 

Out 

C1 

+5V 

Power 

D1 

AD0 

In/Out 

C2 

AD1 

In/Out 

D2 

+5V 

Power 

C3 

AD4 

In/Out 

D3 

AD3 

In/Out 

Summary of Contents for VIM301

Page 1: ...VIM301 PC 104 Plus Graphics Controller Module User Manual Rev 002 December 2015...

Page 2: ...dimensions consumption current software compatibility corrections to the text and illustrations VIM301 November 2009 001b Minor additions to subsections 3 2 5 3 2 11 VIM301 November 2009 002 Complian...

Page 3: ...3 2 2 Video BIOS 16 3 2 3 Video Mode Selector 17 3 2 4 PCI Configuration and Video Mode Selector 18 3 2 5 RGB Connector 19 3 2 6 LVDS1 Connector 19 3 2 7 LVDS2 Connector 21 3 2 8 Flat Panel 1 Connect...

Page 4: ...Figure 3 13 XP11 Connector 26 Figure 3 14 XS1 Connector 28 Figure 3 15 XS2 Connector 30 Figure 3 16 XP1 Connector 31 Figure 4 1 External Devices Connection 33 All information in this document is prov...

Page 5: ...e surface of the heatsink and some components can get very hot during operation Take due care when handling avoid touching hot surfaces Caution Electric Shock This symbol warns about danger of electri...

Page 6: ...sensitive components as well Please keep in mind that any physical damage to this product is not covered under warranty Note This product is guaranteed to operate within the published temperature ran...

Page 7: ...ed to the temperatures below 0 C for a long time it is necessary to keep it at normal conditions for at least 24 hours before unpacking Do not keep the product close to a heat source Following ESD pre...

Page 8: ...ts products Fastwel shall have no liability for direct or consequential damages of any kind arising out of sale delay in delivery installation or use of its products If a product should fail through F...

Page 9: ...ing on version VIM301 allows connection of the following displays Analog CRT monitor with RGB interface Up to two LCD panels with Flat Panel FP interface Up to two LCD panels with single channel LVDS...

Page 10: ...ry for different versions and generations of the module 1 2 VIM301 Versions The table below presents description of the module versions Table 1 1 VIM301 Versions VIM301 Lynx3DM8 8 MB RAM PC 104 Plus c...

Page 11: ...part for connection of up to four video cameras Leotronics 2067 2122 1 1 Contacts for crimping for Leotronics 2067 2122 connector Leotronics 2066 2000 14 14 Ribbon cable connector for connection of 4...

Page 12: ...in processor Video BIOS Soldered 64 KB BIOS chip ACPI 1 0 compatible Interface connectors PCI 104 PCI PC 104 ISA One RGB interface Up to two LVDS interfaces Up to two Flat Panel FP interfaces One SGD...

Page 13: ...age V Power Voltage Range V Version Consumption Current A PC 104 and PCI 104 5 from 4 75 to 5 25 VIM301 01 0 6 VIM301 02 1 VIM301 03 0 6 VIM301 04 0 6 VIM301 05 1 The 12 V voltage is not used by the m...

Page 14: ...0 0 2 Figure 2 1 VIM301 05 Overall and Mounting Dimensions 2 6 MTBF MTBF for VIM301 is 100000 hours The value is calculated according to Telcordia Issue 1 model Method I Case 3 for continuous operatio...

Page 15: ...Bus SAA7111A EVIP LVDS 2 Flat Panel 2 LVDS 1 Flat Panel 1 CRT RGB SA1 Spartan IIE XC2S50E FPGA EEPROM Optional Power AD9985 ATmega8 AVR DS90C385A SGD Planar DC DC 3 3V DC DC 2 5V DC DC 1 8V Lynx3DM8 V...

Page 16: ...deo mode selector PCI configuration switch RGB connector LVDS1 and LVDS2 connectors Flat Panel1and Flat Panel2 connectors SGD 4 bit connector for EL Planar panel Video input connector 4 channels PCI 1...

Page 17: ...n VIM301 V I M 3 0 1 U s e r M a n u a l 15 2 0 1 5 F a s t w e l v 0 0 2 Figure 3 2 Top Side Connectors and Main Components Layout The layout differ for various versions of the module The figure abov...

Page 18: ...icates with other modules in stack via PCI bus PC 104 Plus connector The display controller features the 32 bit VGA core 200 MHz RAMDAC and ability to work with three displays RGB FP and LVDS interfac...

Page 19: ...ding Video Modes Switch Number Switch Position Adjusted Parameters 1 Flat Panel 1 interface type 0 1 Color TFT Color STN 2 Flat Panel 1 clock frequency type 0 1 No inversion Inverted 4 3 Flat Panel 1...

Page 20: ...IDSEL0 INTA GNT0 REQ0 CLK0 IDSEL1 INTB GNT1 REQ1 CLK1 IDSEL2 INTC GNT2 REQ2 CLK2 IDSEL3 INTD GNT3 REQ3 CLK3 3 Flat Panel 2 and LVDS2 clock frequency type 0 1 No inversion Inverted 4 Flat Panel 2 colo...

Page 21: ...GND 5 BLUE 6 GND 7 HSYNC 8 VSYNC 9 SCL 10 SDA Figure 3 5 XP2 Connector 3 2 6 LVDS1 Connector A display with single channel LVDS interface up to four differential data pairs and one differential clock...

Page 22: ...ded providing this voltage to the PCI 104 connector Warning The panel power voltage is specified in documentation accompanying the panel Incorrect voltage setting can damage the panel It is allowed to...

Page 23: ...ader pinout is presented in the table below Table 3 7 LVDS2 XP10 Connector Pinout Pin Signal Pin Signal 1 VCC_LVDS2 2 VCC_LVDS2 3 GND 4 GND 5 TX0 6 TX0 7 GND 8 TX1 9 TX1 10 GND 11 TX2 12 TX2 13 GND 14...

Page 24: ...w e l v 0 0 2 Table 3 8 XP13 Jumper Contacts Designation Pin Function 1 5V 2 VCC_LVDS2 3 3 3V Figure 3 9 XP13 Jumper Switch Table 3 9 LVDS2 Power Voltage Selection XP13 Jumper Position VCC_LVDS2 Volta...

Page 25: ...switch while the power is off XP5 header pinout is presented in the table below Table 3 10 Flat Panel 1 XP5 Connector Pinout Pin Signal Pin Signal 1 GND 2 GND 3 VBIASEN 4 FPVDDEN 5 DATA0 6 DATA1 7 DA...

Page 26: ...111196 9 18 or 24 bit panels are supported settings can be changed using SA2 DIP switch while the power is off XP6 header pinout is presented in the table below Table 3 11 Flat Panel 2 XP6 Connector P...

Page 27: ...to set resolution 640 480 and 18 or 24 bit mode for Flat Panel 1 or 2 depending on what interface is selected SA2 switch 5 as a source for conversion For VIM301 generations 2 0 and higher it is possib...

Page 28: ...operating systems the video capture function of VIM301 is enabled with DirectShow driver from Silicon Motion 12 V power voltage for video cameras is supplied to XP11 connector from PC 104 Plus connec...

Page 29: ...D5 In Out B3 GND Power A4 C BE0 In Out B4 AD7 In Out A5 GND Power B5 AD9 In Out A6 AD11 In Out B6 A7 AD14 In Out B7 AD13 In Out A8 B8 C BE1 In Out A9 B9 GND Power A10 GND Power B10 A11 STOP In Out B11...

Page 30: ...Y In Out D13 C14 D14 C BE2 In Out C15 AD17 In Out D15 GND Power C16 GND Power D16 AD19 In Out C17 AD22 In Out D17 C18 IDSEL1 In D18 IDSEL2 In C19 D19 IDSEL3 In C20 AD25 In Out D20 GND Power C21 AD28 I...

Page 31: ...ed on the module is AMP 1375795 2 Its pinout is presented in the table below Table 3 15 XS2 Connector Pinout Contact Signal In Out Contact Signal In Out A1 B1 GND Power A2 B2 A3 B3 5V Power A4 B4 A5 B...

Page 32: ...t Signal In Out Contact Signal In Out C2 D2 C3 D3 C4 D4 C5 D5 C6 D6 C7 D7 C8 D8 C9 D9 C10 D10 C11 D11 C12 D12 C13 D13 C14 D14 C15 D15 C16 D16 5V Power C17 D17 C18 D18 GND Power C19 D19 GND Power In th...

Page 33: ...03 and VIM30105 versions If a PC 104 or PC 104 Plus power supply unit is installed in the stack the module is powered via PC 104 Plus connectors contacts The auxiliary power connector XP1 is optional...

Page 34: ...ringement of these rules ESD Sensitive Equipment This product comprises electrostatically sensitive components Please follow the ESD safety instructions to ensure module s operability and reliability...

Page 35: ...nections VIM301 V I M 3 0 1 U s e r M a n u a l 33 2 0 1 5 F a s t w e l v 0 0 2 4 2 Connection of Peripheral Devices The following diagram illustrates external connections Figure 4 1 External Devices...

Page 36: ...P2 header except VIM301 02 LCD panel with FP interface 9 12 18 24 bit color resolutions 640 480 800 600 1024 768 1280 1024 connected to XP5 header LCD panel with LVDS interface 1 channel 9 12 18 24 bi...

Page 37: ...Graphics Controller Driver Installation Graphics controller drivers for different operating systems as well as the driver for Windows XP can be found at ftp ftp prosoft ru pub Hardware Fastwel CPx VIM...

Page 38: ...Installation of Drivers for Windows XP XPe VIM301 V I M 3 0 1 U s e r M a n u a l 36 2 0 1 5 F a s t w e l v 0 0 2 In the Desktop window select My Computer In File menu select Manage...

Page 39: ...w e l v 0 0 2 In the Computer Management window select Device Manager In the right pane open the Display adapters item select Video Controller VGA Compatible and click the right mouse button In the c...

Page 40: ...a l 38 2 0 1 5 F a s t w e l v 0 0 2 The window Hardware Update Wizard opens In this window check the option No not this time and press the Next button In the next Hardware Update Wizard window check...

Page 41: ...w check the option Don t search I will choose the driver to install and press Next to proceed In the Install from disk window press Browse button The window Locate File appears In this window find the...

Page 42: ...1 5 F a s t w e l v 0 0 2 In Install from disk window press In Hardware Update Wizard window select Silicon Motion Lynx3DM from the Model list and press Next In the next Hardware Update Wizard window...

Page 43: ...anel Installation Setup exe is the Control Panel installation utility for Silicon Motion Lynx3DM Lynx3DM controllers It is located at ftp ftp prosoft ru pub Hardware Fastwel CPx VIM301 Software Utils...

Page 44: ...l v 0 0 2 Press Finish in the Setup Complete window The Control Panel is now installed 5 3 Lynx3DM Controller Video Input Driver Installation The video capture driver is located at ftp ftp prosoft ru...

Page 45: ...of Drivers for Windows XP XPe VIM301 V I M 3 0 1 U s e r M a n u a l 43 2 0 1 5 F a s t w e l v 0 0 2 In the Control Panel window select Add Hardware item Add Hardware Wizard window appears Click on...

Page 46: ...V I M 3 0 1 U s e r M a n u a l 44 2 0 1 5 F a s t w e l v 0 0 2 If you see Hardware Update Wizard windows appear click Cancel to close these windows In Add Hardware Wizard window select Yes I have al...

Page 47: ...0 1 5 F a s t w e l v 0 0 2 In the next Add Hardware Wizard window select Add a new hardware device item from the Installed hardware list and click Next In the next Add Hardware Wizard window select...

Page 48: ...M a n u a l 46 2 0 1 5 F a s t w e l v 0 0 2 In the opened Add Hardware Wizard window select Show All Devices item from the Common hardware types list and click Next In the next Add Hardware Wizard w...

Page 49: ...0 0 2 In Locate File window find a folder where the target file is stored and click Open in the sample below the file smivcap inf is located in C Utils sm7xx VidCap WDMnew folder Click OK in Install...

Page 50: ...w click Continue Anyway In the process of installation the operating system may require to locate some missing system files For the files with sys extention stream sys ks sys etc it is necessary to sp...

Page 51: ...check the video input subsystem functionality it is necessary to have a video signal source PAL NTSC or SECAM connected to VIM301 03 or VIM301 05 video input The sample below describes manupulations w...

Page 52: ...he file vcap722 GRF located in DXUtils folder After loading the file vcap722 GRF the graph representing a video capture channel using SmiVCap driver is displayed in the GraphEdit program main window B...

Page 53: ...Installation of Drivers for Windows XP XPe VIM301 V I M 3 0 1 U s e r M a n u a l 51 2 0 1 5 F a s t w e l v 0 0 2...

Page 54: ...ave been prepaid in full Other terms and conditions of cooperation should be made in writing 3 3 Any delivery of Fastwel electronics is submitted with the right package in accordance with the current...

Reviews: